2.1 TECHNICAL DATA
O
PERATION AND CONTROL
Lamp operation 24V DC/max. 40mA (green)
Output regulator - Potentiometer 10kOhm
Technical Data
Watts
Voltage
GIU 2.5 BI
2500
208v & 240v, 60 cycle, 1 ph
GIU 2.5 BI
2500
230v 50 cycle, 1 ph
GIU 3.5 BI
3500
208v & 240v, 60 cycle, 1 ph
GIU 3.5 BI
3500
230v, 50 cycle, 3ph
GIU 5.0 BI
5000
208v, 60 cycle, 3ph
GIU 5.0 BI
5000
440v, 60 cycle, 3ph
GIU 5.0 BI
5000
400v, 50 cycle, 3ph
GIU 3.5 DUAL BI
3500 X 2
208v, 60 cycle, 3ph
GIU 3.5 DUAL BI
3500 X 2
230v 50 cycle, 3ph
GIU 5.0 DUAL BI
5000 X 2
208v, 3ph
GIU 5.0 DUAL BI
5000 X 2
400v, 50 cycle, 3ph
GIU 5.0 DUAL BI
5000 X 2
440v, 60 cycle, 3ph
GIWOK 3.5 BI
3500
208v &240v, 60 cycle, 1 ph
GIWOK 3.5 BI
3500
230v, 50 cycle, 1 ph
GIWOK 5.0 BI
5000
208v, 60 cycle, 3ph
GIWOK 5.0 BI
5000
400v, 50 cycle, 3ph
A) Single Built-In Units
B) Double Built-In Units
C) Built-In Wok Units
O
PERATING CONDITIONS
!
Max. tolerance of the nominal supply voltage
+6/ -10%
!
Supply frequency
50/ 60 Hz
!
Protection class
IP 43
!
Minimal diameter of the pan
12 cm (5 inches)
3. INSTALLTION
3.1 R
EQUIRMENTS OF INSTALLATION
The underside and sides of the induction unit must be absolutely clear of obstructions to provide for adequate cool-
ing air to enter and exhaust. Cooling air enters from the bottom of the unit and is discharged either from the sides
(single or wok units) or from the rear (double units). An air intake kit is provided to ensure adequate cooling air is
brought to the unit. A minimum of 30 sq inch opening must be provided for the heated air to be discharged into
the room.
IMPORTANT
I
NSTALLATION AMBIENCE
Max. ambient temperature
storage > -20o - + 70o C
Function > +5 - +40o C
Max. relative humidity of air
storage > 10% - 90%
Function > 30% - 90%
Page 4