Siting
The base on which the unit is to be sited, must be capable of
adequately supporting the weight of the appliance and any
ancillary equipment. (Refer to dimentions and specifications
in this manual). Once in position check that the equipment is
level, both front to back, side to side and diagonally. Adjust if
necessary.
The Electric Chain Griddle must be level front to back, side to
side and diagonally. This leveling must be done with the unit
under the hood and in its normal operational position.
Casters & Leveling
1. The front casters on the unit are equipped with brakes to
limit movement of the range without relying on the
electrical connection to limit appliance movement.
2. A restraint can be attached to the unit near the electrical
connection. If the restraint
is disconnected, be sure to
reconnect it after the range
has been returned to its
originally installed position.
3. Each caster has a threaded
stem to aid in leveling only.
No caster should be adjusted
beyond a maximum of
one-half inch, (1/2”/13mm)
of exposed thread with the
locking nut tight against the
stand leg, as shown.
Ventilation Air
The electric Chain Griddle (CGC) is intended to be installed
under a ventilation hood.
Proper operation of exhaust fans (proper speed, rotation and
adjustment) is essential. In addition, a make-up air system
(HVAC) for the kitchen supply fresh air is recommended.
Any ventilation system will break down if improperly
maintained. The duct system, the hood, and filters must be
cleaned on a regular basis and kept grease free.
1/2
"
(13mm)
MAX
1/2
"
(13mm)
MAX
Electrical Connections
The Garland ECG series complies with the standards
CSA C22.2 no. 109 – latest edition, the UL197 – latest
edition and the ANSI/NSF 4 – latest edition. The installation
& connection of this appliance must comply with current
codes. In Canada – the Canadian Electrical Code part 1 and in
the USA – the National Electrical Code.
A qualified person as required by the local electrical
authorities must install this equipment.
CAUTION: Prior to installation, check the electrical supply
to ensure input voltage and phase match the equipment
voltage rating and phase. Before attempting the electrical
connection, ensure that the equipment’s electrical
characteristics agree. See data plate located on the bottom
of the control section near the front.
On Electric Chain Griddles, the supply entrance is located
at the rear of the main bottom. The supply terminal block is
accessible from the front.
The electrical supply must be adequate for the voltage,
phase and current marked on the rating plate.
NOTE: A means of disconnection from the supply having
a contact separation of at least 3 mm in all poles must be
incorporated in the fixed wiring.
WARNING: THIS APPLIANCE MUST BE GROUNDED.
Commissioning
Ensure all circuit breakers located behind the access door on
the control panel are set to the “ON” position.
1. Ensure that all controls are in the “OFF” position and turn
on the main electrical supply.
2. Operate each section of the unit in accordance with the
operating instructions provided in this manual.
3. Check that the product functions correctly and the
voltage supply to the unit does not drop by more than
5% when all sections are operated simultaneously.
When the operation has been checked, hand the manual to
the user or purchaser for retention and instruct them in the
efficient and safe operation of the appliance.