Siting

The base on which the unit is to be sited, must be capable of 
adequately supporting the weight of the appliance and any 
ancillary equipment. (Refer to dimentions and specifications 
in this manual). Once in position check that the equipment is 
level, both front to back, side to side and diagonally. Adjust if 
necessary.

The Electric Chain Griddle must be level front to back, side to 
side and diagonally. This leveling must be done with the unit 
under the hood and in its normal operational position.

Casters & Leveling

1.  The front casters on the unit are equipped with brakes to 

limit movement of the range without relying on the 
electrical connection to limit appliance movement.

2.  A restraint can be attached to the unit near the electrical 

connection. If the restraint 
is disconnected, be sure to 
reconnect it after the range 
has been returned to its 
originally installed position.

3.  Each caster has a threaded 

stem to aid in leveling only.
No caster should be adjusted 
beyond a maximum of 
one-half inch, (1/2”/13mm) 
of exposed thread with the 
locking nut tight against the 
stand leg, as shown.

Ventilation Air

The electric Chain Griddle (CGC) is intended to be installed 
under a ventilation hood.

Proper operation of exhaust fans (proper speed, rotation and 
adjustment) is essential. In addition, a make-up air system 
(HVAC) for the kitchen supply fresh air is recommended.

Any ventilation system will break down if improperly 
maintained. The duct system, the hood, and filters must be 
cleaned on a regular basis and kept grease free.

1/2

"

(13mm)

MAX

1/2

"

(13mm)

MAX

Electrical Connections

The Garland ECG series complies with the standards 
CSA C22.2 no. 109 – latest edition, the UL197 – latest 
edition and the ANSI/NSF 4 – latest edition. The installation 
& connection of this appliance must comply with current 
codes. In Canada – the Canadian Electrical Code part 1 and in 
the USA – the National Electrical Code.

A qualified person as required by the local electrical 
authorities must install this equipment.

CAUTION: Prior to installation, check the electrical supply 
to ensure input voltage and phase match the equipment 
voltage rating and phase. Before attempting the electrical 
connection, ensure that the equipment’s electrical 
characteristics agree. See data plate located on the bottom 
of the control section near the front.

On Electric Chain Griddles, the supply entrance is located 
at the rear of the main bottom. The supply terminal block is 
accessible from the front.

The electrical supply must be adequate for the voltage, 
phase and current marked on the rating plate.

NOTE: A means of disconnection from the supply having 
a contact separation of at least 3 mm in all poles must be 
incorporated in the fixed wiring.

WARNING: THIS APPLIANCE MUST BE GROUNDED.

Commissioning

Ensure all circuit breakers located behind the access door on 
the control panel are set to the “ON” position.

1.  Ensure that all controls are in the “OFF” position and turn 

on the main electrical supply.

2.  Operate each section of the unit in accordance with the 

operating instructions provided in this manual.

3.  Check that the product functions correctly and the 

voltage supply to the unit does not drop by more than 
5% when all sections are operated simultaneously.

When the operation has been checked, hand the manual to 
the user or purchaser for retention and instruct them in the 
efficient and safe operation of the appliance.

INSTALLATION Continued

Summary of Contents for ECG-24R

Page 1: ...o Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB3 1DQ ENGLAND Telephone 081 561 0433 Fax 081 848 0041 Part 3073400 01 28 08 2004 Garland Commercial Industries Inc FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION...

Page 2: ...tate of california to cause cancer and or birth defects or other reproductive harm Installation and servicing of this product could expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer ...

Page 3: ...ing 6 Casters Leveling 6 Ventilation Air 6 Electrical Connections 6 Commissioning 6 OPERATING INSTRUCTIONS 7 Griddles 7 Griddle Start Up 7 Griddle Shut Down 7 Thermostat Temperature Verification 7 MAINTENANCE CLEANING 8 Preparing A New Griddle 8 Seasoning The Griddle 8 General Cleaning 8 Cleaning Stainless Steel 8 Griddle Cleaning 8 Griddles Do s Don ts 9 Servicing 9 Safety 9 ...

Page 4: ... 30 31 0 31 0 31 0 53 8 ECG 48R 48 1219mm 208 0 17 20 5 60 6 00 5 60 48 3 46 6 48 3 82 7 500 lbs 227 kg 240 0 17 20 5 60 6 00 5 60 41 9 40 4 41 9 71 7 ECG 60R 60 1524mm 208 0 21 50 6 90 7 30 7 30 59 1 59 1 60 8 103 4 600 lbs 277 kg 240 0 21 50 6 90 7 30 7 30 51 2 51 2 52 7 89 6 ECG 72R 72 1929mm 208 0 25 80 8 60 8 60 8 60 71 6 71 6 71 6 124 0 700 lbs 318 kg 240 0 25 89 8 60 8 60 8 60 62 1 62 1 62 ...

Page 5: ...lified person must perform the installation in accordance with local codes Always follow these safety instructions when operating the Electric Chain Griddle Only qualified persons must operate the unit Do Not operate without reading this manual Do Not operate the product unless it has been properly installed and grounded Do Not operate the product unless all service and access panels are in place ...

Page 6: ...nd ECG series complies with the standards CSA C22 2 no 109 latest edition the UL197 latest edition and the ANSI NSF 4 latest edition The installation connection of this appliance must comply with current codes In Canada the Canadian Electrical Code part 1 and in the USA the National Electrical Code A qualified person as required by the local electrical authorities must install this equipment CAUTI...

Page 7: ... to the OFF position 2 Switch OFF all sections 3 Switch OFF main power switch on the control panel ThermostatTemperatureVerification 1 Set each thermostat dial to the same temperature Unless the grill temperature is being verified for a specific function use 350 F for the temperature setting Preheat the grill for 30 minutes before proceeding NOTE Each minor line on the thermostat scale is 5 degree...

Page 8: ...ase or oil Do not use ordinary steel scrapers or knives as particles of iron may become embedded and rust NEVER USE STEEL WOOL Griddle Cleaning After Each Use 1 Using a traditional 64mm 76mm 2 1 2 3 scraper or spatula scrape the griddle surface to remove food particles and oil residues towards the grease trough using even front to back strokes Deposit debris into the chute 2 Using a clean cloth ru...

Page 9: ...le The edges of these utensils are sharp and will create divots that oil can collect in and caramelize which will cause sticking 3 Do not use the griddle as a hot top A large pan or pot will trap heat and can cause the griddle plate to warp 4 Do not overheat the griddle to preheat faster Preheating only takes 15 10 minutes Servicing To ensure efficient and safe operation of the appliance it is rec...

Page 10: ...Part 3073400 01 28 08 Page 10 ...

Page 11: ... tranchants et créent de petites fi ssures dans lesquelles l huile s infi ltre et caramélise 3 Ne pas utiliser le gril comme surface chaude Une grande casserole ou un chaudron emprisonne la chaleur et peuvent provoquer une déformation de la plaque du gril 4 Ne pas surchauff er le gril pour préchauff er plus rapidement Préchauff er ne prends que 15 à 20 minutes Entretien Pour assurer le fonctionnem...

Page 12: ...fer peuvent s y encastrer et rouiller NE JAMAIS UTILISER DE LA LAINE D ACIER Nettoyage Du Gril Apres Chaque Usage 1 À l aide d un racloir traditionnel 64mm 76mm 2 1 2 3 ou d une spatule racler la surface du gril pour enlever les particules de nourriture et les résidus d huile vers le dalot à graisse en eff ectuant des mouvements réguliers de l arrière à l avant Déposer les débris dans l auge 2 En ...

Page 13: ...bserver l indicateur ambre pour la zone dont la température est mesurée Quand le témoin ambre est allumé le brûleur de cette zone est également allumé Quand le témoin ambre s éteint noter la température INSTRUCTIONS D UTILISATION suite La température mesurée au moment où le témoin ambre s éteint ne devrait pas être à 5 F de la température du thermostat Si l erreur est supérieure à 5 F consulter un...

Page 14: ...ur la surface du gril car ils pourraient égratigner ou abîmer la surface et dégrader les propriétés cuisantes ou anti adhérentes du produit Ne jamais saler les aliments sur le gril afi n d éviter une accumulation de résidus gommeux diffi ciles à nettoyer Éviter de frapper la surface du gril avec les bordures d une spatule pour ne pas l abîmer Les températures les plus fréquemment utilisées sont 14...

Page 15: ... fois la cuisinière replacée à son emplacement d origine 1 2 13mm MAX 1 2 13mm MAX 3 Chaque roulette est dotée d une tige fi letée destinée uniquement à mettre l appareil de niveau Aucune roulette ne doit être réglée au delà d un maximum d un demi pouce 1 2 po 13 mm de fi letage exposé avec l écrou de blocage contre le pied comme illustré Ventilation Le gril électrique à chaîne GEC doit être insta...

Page 16: ...ent manuel concerne le gril électrique à chaîne Le lecteur utilisateur doit adapter son contenu aux besoins applicables En cas de doute sur l interprétation des consignes relatives aux grils électriques à chaîne de Garland communiquer avec l Agence de service agrée ou notre Département de Service à la clientèle au numéro de téléphone 1 800 427 6668 L installation doit être eff ectuée par une perso...

Page 17: ...31 0 53 8 ECG 48R 48 Po 1219mm 208 0 17 20 5 60 6 00 5 60 48 3 46 6 48 3 82 7 500 lbs 227 kg 240 0 17 20 5 60 6 00 5 60 41 9 40 4 41 9 71 7 ECG 60R 60 Po 1524mm 208 0 21 50 6 90 7 30 7 30 59 1 59 1 60 8 103 4 600 lbs 277 kg 240 0 21 50 6 90 7 30 7 30 51 2 51 2 52 7 89 6 ECG 72R 72 Po 1929mm 208 0 25 80 8 60 8 60 8 60 71 6 71 6 71 6 124 0 700 lbs 318 kg 240 0 25 89 8 60 8 60 8 60 62 1 62 1 62 1 107...

Page 18: ...ement 6 Roulettes 6 Ventilation 6 Connexions Électriques 6 Mise En Service 7 INSTRUCTIONS D UTILISATION 7 Grils 7 Utilisation Du Gril 7 Éteindre Le Gril 7 Vérifi cation De La Température Du Thermostat 7 ENTRETIEN ET NETTOYAGE 9 Spreparer Un Nouveau Gril 9 Stabiliser Le Gril 9 Nettoyage Général 9 Nettoyage De L acier Inoxydable 9 Nettoyage Du Gril 9 Grill À Faire Et À Ne Pas Faire 10 Entretien 10 S...

Page 19: ...e comme causant le cancer et ou des malformations congénitales ou d autres problèmes de reproduction L installation et l entretien de ce produit peut vous exposer aux poussières de laine de verre fibres céramiques L inhalation de ces particules de laine de verre ou de fibres céramiques est reconnue par l état de Californie comme causant le cancer ...

Page 20: ...io L4W 1X4 CANADA Téléphone 905 624 0260 Télécopieur 905 624 5669 Enodis UK LTD Swallowfi eld Way Hayes Middlesex UB3 1DQ ANGLETERRE Téléphone 081 561 0433 Télécopieur 081 848 0041 Pièce n 3073400 01 28 08 2004 Garland Commercial Industries Inc POUR VOTRE SÉCURIT NE PAS STOCKER NI UTILISER D ESSENCE OU D AUTRES VAPEURS OU LIQUIDES INFLAMMABLES À PROXIMITÉ DE CET APPAREIL OU DE TOUT AUTRE APPAREIL ...

Reviews: