FGP Series Football Goal Posts   

 

Parts Checklist 

Verify all parts listed on packing list are present prior to installation. 

Football Goal Post Components 

PERMANENT/SLEEVE MODELS

FGP401S

FGP402S

FGP601S

FGP602S

POST DIA.

POST OFFSET

UPRIGHT SPACING

23'-4"

18'-6"

23'-4"

18'-6"

HS.

COLLEGE

HS

COLLEGE

ITEM PART NUMBER

DESCRIPTION

QTY

QTY

QTY

QTY

1

155752729

WINDFLAG ENDCAP ASSEMBLY  (PAIR)

1

1

1

1

945751120

CROSSBAR WELDMENT, 4.5 HS X 4.5 POST

1

945751121

CROSSBAR WELDMENT, 4.5 COLL X 4.5 POST

1

945751719

CROSSBAR WELDMENT, 4.5 HS X 5.56 POST

1

945751713

CROSSBAR WELDMENT, 4.5 COLL X 5.56 POST

1

3

945751122

BRKT WLDMT, UPRIGHT, 4-1/2" CROSSBAR

2

2

2

2

945752116

POST WELDMENT, 4 1/2" DIA, 5 FT FGP  

1

1

945751711

POST WELDMENT, 5 9/16" DIA, 5 FT FGP  

1

1

5

945755242

UPRIGHT-ALUMINUM, 20' GOAL POST

2

2

2

2

155752638

KIT, HARDWARE-FGP401S AND FGP402S  

1

1

155752640

KIT, HARDWARE-FGP601S AND FGP602S 

1

1

101152132

THREADED ROD, 1/2-13 X 10" LG

1

1

945751724

THREADED ROD, 3/4" DIA X 12-1/2" LONG

1

1

9.2 502-8-13-60

HEX BOLT, 1/2-13 UNC X 3.75

4

4

4

4

502-8-13-88

HEX BOLT, 1/2-13 UNC X 5.5

1

1

502-8-13-104

HEX BOLT, 1/2-13 UNC X 6.5

1

1

9.4 502-8-13-96

HEX BOLT, 1/2-13 UNC X 6

2

2

2

2

9.5 511-6-16-8Z

SET SCREW, CUP POINT 3/8-16 UNC X 0.5 Z

4

4

2

2

9.6 515- 8-13-16

SET SCREW, SQ HEAD 1/2-13 UNC X 1

6

6

6

6

541-8-13

HEX NUT 1/2-13

2

2

541-12-10

HEX NUT 3/4-10

2

2

9.9 545-8-13

HEX NUT, NYLON LOCK 1/2-13

7

7

7

7

9.10 561-8

FLAT WASHER 1/2

8

8

8

8

9.11 941752635

INST'L INSTR FGP SERIES GOAL POSTS 

1

1

1

1

*Note:  Quantities shown are for one goal.  FGP goals sold in pairs.

9.7

4 1/2" OD

60"

5 9/16" OD

72"

2

4

9.3

9

9.1

Note: 

Part numbers that have a “Y” added to the end of the number indicate the crossbar and uprights are painted yellow.  

Part numbers that have a “W” added to the end of the number indicate the crossbar and uprights are painted white. 

 
 
 
 
 

Summary of Contents for PSS FGP400 Series

Page 1: ...GP400 and FGP600 series Installation and Maintenance Instructions Please read all instructions before attempting installation of these units SAVE THESE INSTRUCTIONS FOR FUTURE USE PUBLICATION NO Revis...

Page 2: ...aimer 3 Parts Checklist 4 Tools Required 6 Preparation for Installation 7 Post Installation Permanent Mount 8 Post Installation with Ground Sleeves 9 Post Installation Plate Mount 11 Crossbar Installa...

Page 3: ...up of the Football Goal Post No one under the age of 18 should attempt assembly or set up of the unit unless properly supervised To prevent normal wear and tear from shortening the life of the unit p...

Page 4: ...RE FGP401S AND FGP402S 1 1 155752640 KIT HARDWARE FGP601S AND FGP602S 1 1 101152132 THREADED ROD 1 2 13 X 10 LG 1 1 945751724 THREADED ROD 3 4 DIA X 12 1 2 LONG 1 1 9 2 502 8 13 60 HEX BOLT 1 2 13 UNC...

Page 5: ...4 4 4 502 8 13 88 HEX BOLT 1 2 13 UNC X 5 5 1 1 502 8 13 104 HEX BOLT 1 2 13 UNC X 6 5 1 1 9 4 502 8 13 96 HEX BOLT 1 2 13 UNC X 6 2 2 2 2 9 5 511 6 16 8Z SET SCREW CUP POINT 3 8 16 UNC X 0 5 Z 4 4 4...

Page 6: ...IA X 12 1 2 LONG 1 541 8 13 HEX NUT 1 2 13 10 541 12 10 HEX NUT 3 4 10 10 945752124 TUBE GROUND SLEEVE 4 1 2 POST 1 945751723 TUBE GROUND SLEEVE 5 9 16 POST 1 Note Quantities shown are for one sleeve...

Page 7: ...or 602 series goals 5 9 16 diameter posts the center of the hole must be 6 2 3 4 behind the front of the end zone end line as shown above 2 Dig hole as shown in Figure 1 Figure 2 or Figure 3 dependin...

Page 8: ...s on each end of the field dug for the sleeve mounts 2 Add 6 of gravel to the bottom of the hole 3 Insert a drainage tube approximately 8 10 long in the center of each 4 Install one the threaded rods...

Page 9: ...ires a permanent mounted post or plate mounted post proceed to the appropriate section 1 Stretch a string the length of the field centered on the playing field This string should be over the center of...

Page 10: ...ctions 5 If post requires adjustment to plumb remove the post from the sleeve and loosen the nuts on the threaded rods Tighten one of the nuts on one side of the threaded rod to shift the rod to the s...

Page 11: ...nd of the field dug for the post mounts 2 Add 6 of gravel to the bottom of each hole 3 Install a nut item 9 7 onto each anchor rod item 6 Screw the nut onto the rod 4 Make sure 4 of thread is exposed...

Page 12: ...s being careful to not damage the exposed threads 3 Install another flat washer item 9 7 on each rod and then install a nut item 9 9 on each rod 4 Tighten all four nuts enough to make sure the post is...

Page 13: ...he crossbar in the post until it is level 8 Install the two setscrews item 9 6 and tighten securely 9 Recheck crossbar for level and recheck alignment to the end zone end line 10 Using the hole on the...

Page 14: ...he upright to the vertical position and snug the two setscrews item 9 6 in the bracket 6 Using a level adjust the upright for plumb 7 When the upright is plumb tighten both setscrews securely item 9 6...

Page 15: ...tween yearly inspections 2 It is recommended that yearly inspections be conducted to determine if any bolts or other hardware has become worn or loosened 3 During yearly inspections check all joints t...

Page 16: ...ed Holdings LLC Performance Sports Systems Gared Sports 9200 E 146th Street 9200 E 146th Street Noblesville IN 46060 Noblesville IN 46060 800 848 8034 800 325 2682 www perfsports com www garedsports c...

Reviews: