![Gardner Denver SAVG2-100 Installation, Operating & Service Manual Download Page 74](http://html1.mh-extra.com/html/gardner-denver/savg2-100/savg2-100_installation-operating-and-service-manual_563821074.webp)
13-21-615 v01 Page 73
Rotating machinery can cause personal injury or death. Turn the unit completely
off, open the main disconnect, lockout and tagout before servicing the coupling.
SECTION 7
COUPLING
Figure 7-1 INSTALLATION OF COUPLING CUSHIONS
COUPLING
- The motor and compressor are direct connected by a resilient type flexible coupling with a
single cushion. The coupling does not require lubrication.
If maintenance on mating parts is required, reassemble coupling as follows: