- 68 -

Who to contact if you have a Warranty Claim

Warranty and Claim Information

7.  The service contractor will be allowed 2 hours

for an initial inspection of the dryer.  If, at this time,
the cause of failure is determined to be non warranty,
(see what is covered and what is not covered) the
distributor will be billed for the inspection. The distributor
can then recover his costs from the end user. If the
failure is within warranty, the service contractor will be
asked to provide an estimate for the cost of the repairs.
Once a price is established, the contractor will be given
permission to proceed.

Not Covered

All FREIGHT DAMAGE CLAIMS

 

are not the responsibility

of the manufacturer and are not covered under warranty as
all products are shipped F.O.B. shipper. Please direct
freight claims to the shipper in questions.

Two mechanics on a warranty job, extra helpers deemed
necessary. (on site personnel should assist as much
as possible)

Overtime hours, weekend labor rates.

Air freight of units or parts. If air freight is required,
the manufacturer will pay the cost of normal ground
transportation and the customer will be liable for costs
above those charges.

Removal or reinstallation of equipment or extra bypassing
to accomplish repairs.

Hot gas valve adjustments or other normal
maintenance items.

Damages due to misapplication, poor maintenance ,
corrosive environments, or other items outside the scope of
manufacture defects.

Covered

Repairs due to defects in materials.

Repairs due to defects in workmanship.

A maximum of 

250

 miles round trip travel for one

service technician at maximum rate of $50.00/hour
and $.35/mile. 

70

 miles will constitute one hour of

drive time.

What is and What is not Covered
Under This Warranty? Claim

RDS Series — 50-1000 SCFM

Section 10

All claims made under this warranty shall be
directed to the:

COMPRESSED AIR TREATMENT DIVISION
at (303) 783-2322

To initiate a possible warranty claim.

1.  Contact the Compressed Air Treatment Division at

303 783-2322 and provide the following information:
a.  Customer name, contact name, phone number,

addresses.

b.  Dryer serial number and model number.
c.  Description of problem or complaint with as

much detail as possible.

5.  Gardner Denver dryer service will ask for a purchase

order at this time. The P.O. will be used in the event
that parts or labor are non-warranty. If  a warranty
situation is deemed to exist, the distributor will not be
billed for the call. Gardner Denver service issues a
warranty number known as an authorization to return
(number) to the distributor at this time.

6.  Gardner Denver service will contact the customer to

determine the nature of the problem and attempt to
solve it over the phone. If the problem cannot be
resolved over the phone, arrangements will be made
for an outside service source to look at the dryer and
determine a course of action for repairs. The
contractor will be given the ATR number as a
reference for the job.

NOTE: MANY REPAIRS ON A REFRIGERATED AIR DRYER
CAN BE DONE BY A TECHNICIAN WITH NO EPA
REFRIGERANT HANDLING CERTIFICATION. THIS WOULD
INCLUDE CONDENSER CLEANING, HOT GAS VALVE
ADJUSTMENTS, DRAIN VALVE AND FAN MOTOR
REPLACEMENT.

CERTIFICATION IS REQUIRED WHEN THE REFRIGERANT
SIDE OF THE SYSTEM NEEDS WORK OR REFRIGERANT
IS PURCHASED AT A WHOLESALER.

Summary of Contents for RDS Series

Page 1: ...Location Typical Installation Piping and Connections Recommended Filters Electrical Connections Drain Valve Time Settings Remote Contact Hook up SECTION 5 Start up and Shut down 15 Hot gas Bypass Valv...

Page 2: ...1 60 1 3 230 3 60 2 4 460 3 60 2 380 3 50 2 5 575 3 60 2 1 50 200 SCFM 2 250 1000 SCFM Derate Flow by 17 for 50 hz C Remote Operation Contacts 48V Max Input Shipped Loose F Packaged Filters Shipped Lo...

Page 3: ...porator causes water vapor in the air to condense removed from the system by means of an automatic drain Refrigerant circuit Refrigerant R 22 gas is pumped at high pressure by a compressor to an air o...

Page 4: ...need to be protected by safety relief valves Refer to OSHA 1910 169 Paragraph B subparagraph 3 and ASME Boiler and Pressure Vessel code section VIII Division 1 UG 125 through UG 136 Also check govern...

Page 5: ...3 3 27 22 46 23 8 25 2 40 1 7 3 9 7 11 7 14 1 14 7 16 7 1 1 2 1 4 285 RDS250 250 14800 1079 230 460 3 60 1 0 1 3 5 27 22 46 23 8 25 2 40 1 7 3 9 7 11 7 14 1 14 7 16 7 1 1 2 1 4 295 RDS300 300 21600 15...

Page 6: ...50A 5 250 SCFM 575 60 3 2 50 17 4 1 43 15 0 70 RDS300A 3 300 SCFM 230 60 3 6 00 50 0 0 91 15 0 25 RDS300A 4 300 SCFM 460 60 3 380 3 50 2 80 25 0 1 83 15 0 70 RDS300A 5 300 SCFM 575 60 3 2 60 25 0 1 83...

Page 7: ...O F 100O F 16000 190 PSIG 400 PSIG RDS250A 4 3 0 15 64 oz 100 PSIG 100O F 100O F 16000 190 PSIG 400 PSIG RDS250A 5 3 0 15 64 oz 100 PSIG 100O F 100O F 16000 190 PSIG 400 PSIG RDS300A 3 7 0 15 48 oz 10...

Page 8: ...300W 5 300 SCFM 575 60 3 RDS400W 3 400 SCFM 230 60 3 RDS400W 4 400 SCFM 460 60 3 380 3 50 3 2 25 0 2 00 15 3 7 RDS400W 5 400 SCFM 575 60 3 RDS500W 3 500 SCFM 230 60 3 9 5 71 0 2 50 15 10 5 RDS500W 4 5...

Page 9: ...190 PSIG 400 PSIG RDS250W 4 15 52 oz 100 PSIG 100 O F 100 O F 190 PSIG 400 PSIG RDS250W 5 RDS300W 3 15 30 oz 100 PSIG 100 O F 100 O F 190 PSIG 400 PSIG RDS300W 4 15 30 oz 100 PSIG 100O F 100O F 190 P...

Page 10: ...in a manner that ensures that corrosive fumes are not introduced into the air system DRYER FAILURE DUE TO ACID OR CORROSIVE SUBSTANCE ATTACK IS CONSIDERED OWNER ABUSE AND WILL NOT BE COVERED AS A WAR...

Page 11: ...eating more heat removal potential and lowering the high side pressure As the pressure drops the valve closes and high side pressure is allowed to increase By monitoring pressure and adjusting water f...

Page 12: ...oltage Caution FAILURE TO INSTALL THE PROPER ELECTRICAL PROTECTION CAN RESULT IN PERSONAL INJURY FIRE EQUIPMENT DAMAGE OR DEATH THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY LACK...

Page 13: ...LIARY AND REMOTE CONTACTS FOR INTERFACE TO CUSTOMER CONTROLS AND AUTOMATION SYSTEMS THESE CONTACTS CAN BE USED FOR REMOTE START AND ALARMS CONNECT THESE CONTACTS ACCORDING TO THE FOLLOWING DIAGRAM RDS...

Page 14: ...ct Ratings on Remote Option Board are 48 VAC DC RDS Series 50 1000 SCFM Installing the Dryer Section 4 4 6 1 Installation Instruction for Remote Option 5 Terminals 1 and 5 are connected Power is suppl...

Page 15: ...STALLATION INSTRUCTIONS AND PROCEDURES COMPLETELY SERIOUS PERSONAL INJURY CAN RESULT IF INSTRUCTIONS ARE NOT CAREFULLY AND COMPLETELY FOLLOWED DO NOT REMOVE REPAIR OR REPLACE ANY ITEM ON THE DRYER WHI...

Page 16: ...liquid refrigerant line as it leaves the condenser in the proximity of the liquid line dryer This thermistor senses the temperature of the refrigerant as it leaves the condenser A signal is sent to th...

Page 17: ...194 0 92 203 0 79 212 0 68 221 0 59 230 0 51 Temperature Resistance Deg F K ohms 58 40 22 4 14 32 163 25 50 99 5 68 62 45 86 40 29 104 26 63 122 18 02 140 12 44 158 8 76 176 6 28 194 4 58 212 3 39 23...

Page 18: ...light mixture of detergent No oil based cleaning solvents should be used for cleaning the unit Annually 1 Tighten all electrical connections Look for broken cracked or bare wires 2 Measure and record...

Page 19: ...er temp thermistor for proper location Verify liquid injection valve connections at valve and control board Verify proper inlet air and ambient conditions Refer to specification table for proper param...

Page 20: ...ssure drop across the dryer Inlet or outlet valves are closed Dirty or plugged filters in air system Frozen heat exchanger Plugged heat exchanger Airflow through the dryer is too high Open valves and...

Page 21: ...21 Notes...

Page 22: ...7009277 7009277 16 PANEL LOUVERED 7009291 7009291 7009292 7009292 17 PANEL LOWER FRONT 7009263 7009263 7009264 7009264 18 PANEL REAR 7009283 7009283 7009284 7009284 19 PANEL RIGHT SIDE 7009270 700927...

Page 23: ...23 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 50 75 SCFM AIR COOLED...

Page 24: ...009278 7009278 16 PANEL LOUVERED 7009293 7009293 7009293 7009293 17 PANEL LOWERFRONT 7009265 7009265 7009265 7009265 18 PANEL REAR 7009285 7009285 7009285 7009285 19 PANEL RIGHTSIDE 7009272 7009272 70...

Page 25: ...25 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 100 125 SCFM AIR COOLED...

Page 26: ...16 PANEL LOUVERED 7009294 7009294 7009295 7009295 17 PANEL LOWER FRONT 7009266 7009266 7009267 7009267 18 PANEL REAR 7009286 7009286 7009287 7009287 19 PANEL RIGHT SIDE 7009273 7009273 7009274 700927...

Page 27: ...27 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 150 200 SCFM AIR COOLED...

Page 28: ...0 7014120 15 PANEL LEFT SIDE 7009280 7009280 7009280 16 PANEL LOUVERED 7009295 7009295 7009295 17 PANEL LOWER FRONT 7009267 7009267 7009267 18 PANEL REAR 7009287 7009287 7009287 19 PANEL RIGHT SIDE 70...

Page 29: ...29 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 250 SCFM AIR COOLED...

Page 30: ...PANEL LEFT SIDE 7009281 7009281 7009281 16 PANEL LOUVERED 7009296 7009296 7009296 17 PANEL LOWER FRONT 7009268 7009268 7009268 18 PANEL REAR 7009288 7009288 7009288 19 PANEL RIGHT SIDE 7009275 700927...

Page 31: ...31 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 300 SCFM AIR COOLED...

Page 32: ...EL LOUVERED 7009296 7009296 7009296 17 PANEL LOWER FRONT 7009268 7009268 7009268 18 PANEL REAR 7009288 7009288 7009288 19 PANEL RIGHT SIDE 7009275 7009275 7009275 20 PANEL TOP 7009303 7009303 7009303...

Page 33: ...33 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 400 SCFM AIR COOLED...

Page 34: ...EL LOUVERED 7009296 7009296 7009296 17 PANEL LOWER FRONT 7009268 7009268 7009268 18 PANEL REAR 7009289 7009289 7009289 19 PANEL RIGHT SIDE 7009275 7009275 7009275 20 PANEL TOP 7009303 7009303 7009303...

Page 35: ...35 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 500 SCFM AIR COOLED...

Page 36: ...VERED 7009297 7009297 7009297 17 PANEL LOWER FRONT 7009268 7009268 7009268 18 PANEL REAR 7009290 7009290 7009290 19 PANEL RIGHT SIDE 7009275 7009275 7009275 20 PANEL TOP 7009303 7009303 7009303 21 REL...

Page 37: ...37 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 650 SCFM AIR COOLED...

Page 38: ...161 17 PANEL LOW ER FRONT 7011158 7011158 7011158 18 PANEL REAR 7011160 7011160 7011160 19 PANEL RIGHT SIDE TOP 7011159 7011159 7011159 20 PANEL TOP 7011162 7011162 7011162 21 RELAY START N A N A N A...

Page 39: ...39 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 800 SCFM AIR COOLED...

Page 40: ...1 7011161 17 PANEL LOWER FRONT 7011158 7011158 7011158 18 PANEL REAR 7011160 7011160 7011160 19 PANEL RIGHT SIDE TOP 7011159 7011159 7011159 20 PANEL TOP 7011162 7011162 7011162 21 RELAY START N A N A...

Page 41: ...41 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 1000 SCFM AIR COOLED...

Page 42: ...7009266 7009267 7009267 18 PANEL REAR 7009286 7009286 7009287 7009287 19 PANEL RIGHT SIDE 7009273 7009273 7009274 7009274 20 PANEL TOP 7009301 7009301 7009302 7009302 21 RELAY START 7009312 7009312 7...

Page 43: ...43 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 150 200 SCFM WATER COOLED...

Page 44: ...67 7009267 7009267 18 PANEL REAR 7009287 7009287 7009287 19 PANEL RIGHT SIDE 7009274 7009274 7009274 20 PANEL TOP 7009302 7009302 7009302 21 RELAY START N A N A N A 22 THERMISTOR COMP DISCHARGE 700933...

Page 45: ...45 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 250 SCFM WATER COOLED...

Page 46: ...8 7009268 18 PANEL REAR 7009288 7009288 7009288 19 PANEL RIGHT SIDE 7009275 7009275 7009275 20 PANEL TOP 7009303 7009303 7009303 21 RELAY START N A N A N A 22 THERMISTOR COMP DISCHARGE 7009330 7009330...

Page 47: ...47 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 300 SCFM WATER COOLED...

Page 48: ...09268 7009268 18 PANEL REAR 7009288 7009288 7009288 19 PANEL RIGHT SIDE 7009275 7009275 7009275 20 PANEL TOP 7009303 7009303 7009303 21 RELAY START N A N A N A 22 THERMISTOR COMP DISCHARGE 7009330 700...

Page 49: ...49 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 400 SCFM WATER COOLED...

Page 50: ...09268 7009268 18 PANEL REAR 7009289 7009289 7009289 19 PANEL RIGHT SIDE 7009275 7009275 7009275 20 PANEL TOP 7009303 7009303 7009303 21 RELAY START N A N A N A 22 THERMISTOR COMP DISCHARGE 7009330 700...

Page 51: ...51 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 500 SCFM WATER COOLED...

Page 52: ...09268 18 PANEL REAR 7009290 7009290 7009290 19 PANEL RIGHT SIDE 7009275 7009275 7009275 20 PANEL TOP 7009303 7009303 7009303 21 RELAY START N A N A N A 22 THERMISTOR COMP DISCHARGE 7009330 7009330 700...

Page 53: ...53 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 650 SCFM WATER COOLED...

Page 54: ...RED 7011161 7011161 7011161 17 PANEL LOW ER FRONT 7011158 7011158 7011158 18 PANEL REAR 7011160 7011160 7011160 19 PANEL RIGHT SIDE TOP 7011159 7011159 7011159 20 PANEL TOP 7011162 7011162 7011162 21...

Page 55: ...55 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 800 SCFM WATER COOLED...

Page 56: ...011158 18 PANEL REAR 7011160 7011160 7011160 19 PANEL RIGHT SIDE TOP 7011159 7011159 7011159 20 PANEL TOP 7011162 7011162 7011162 21 RELAY START N A N A N A 22 THERMISTOR COMP DISCHARGE 7009330 700933...

Page 57: ...57 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 1000 SCFM WATER COOLED...

Page 58: ...58 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 50 200 SCFM 115 1 60 230 1 60...

Page 59: ...59 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 250 500 SCFM 230 3 60...

Page 60: ...60 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 250 500 SCFM 460 3 60...

Page 61: ...61 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 250 300 SCFM 575 3 60...

Page 62: ...62 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 400 500 SCFM 460 3 60...

Page 63: ...63 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 650 SCFM 230 3 60...

Page 64: ...64 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 650 SCFM 460 3 60 575 3 60...

Page 65: ...65 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 800 1000 SCFM 230 3 60...

Page 66: ...66 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 800 1000 SCFM 460 3 60 575 3 60...

Page 67: ...tallation application and maintenance in accordance with the manufacturers written recommendations and specifications for a specific time period outlined below The manufacturers warranty is limited to...

Page 68: ...es round trip travel for one service technician at maximum rate of 50 00 hour and 35 mile 70 miles will constitute one hour of drive time What is and What is not Covered Under This Warranty Claim RDS...

Page 69: ...69 NOTES...

Page 70: ...ill in information and fax to 303 783 2333 RDS Series 50 1000 SCFM Warranty Unit Model Number Unit Serial Number Installation Date Distributor P O Number Initiates service call Fax Number where warran...

Reviews: