Model
Interval
Duration
Interval
Duration
50 SCFM
I1
S3
132
1.5
75 SCFM
I1
S3
132
1.5
100 SCFM
I1
S3
132
1.5
125 SCFM
I1
S3
132
1.5
150 SCFM
I1
S3
132
1.5
200 SCFM
I1
S3
132
2.5
250 SCFM
I1
S2
132
2.5
300 SCFM
I1
S1
132
3.5
400 SCFM
I1
S1
132
3.5
500 SCFM
I1
S1
132
3.5
650 SCFM
I1
S3
132
1.5
800 SCFM
I1
S3
132
1.5
1000 SCFM
I1
S2
132
2.5
AUXILIARY AND REMOTE CONTACTS
- THE DRYER IS
EQUIPPED WITH AUXILIARY AND REMOTE CONTACTS FOR
INTERFACE TO CUSTOMER CONTROLS AND AUTOMATION
SYSTEMS. THESE CONTACTS CAN BE USED FOR REMOTE
START AND ALARMS. CONNECT THESE CONTACTS
ACCORDING TO THE FOLLOWING DIAGRAM.
RDS Series —50-1000 SCFM
Installing the Dryer
Section 4
4.4 Drain Valve Timer Options
4.5 Optional –
Remote Contacts
Jumper
Selection
Drain
Timing (Sec.)
POWER SUPPLY
48VAC/DC MAX.
ALARM SIGNAL OUTPUT
(ON WHEN DRYER IS MALFUNCTIONING)
POWER SUPPLY
48VAC/DC MAX.
DEW POINT ALARM SIGNAL OUTPUT
(ON WHEN DEW POINT IS ABNORMAL)
POWER SUPPLY
48VAC/DC MAX.
RUNNING SIGNAL OUTPUT
(ON WHEN DRYER IS RUNNING)
NO-VOLTAGE
CONTACT
Summary of Contents for RDS Series
Page 21: ...21 Notes...
Page 23: ...23 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 50 75 SCFM AIR COOLED...
Page 25: ...25 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 100 125 SCFM AIR COOLED...
Page 27: ...27 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 150 200 SCFM AIR COOLED...
Page 29: ...29 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 250 SCFM AIR COOLED...
Page 31: ...31 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 300 SCFM AIR COOLED...
Page 33: ...33 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 400 SCFM AIR COOLED...
Page 35: ...35 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 500 SCFM AIR COOLED...
Page 37: ...37 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 650 SCFM AIR COOLED...
Page 39: ...39 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 800 SCFM AIR COOLED...
Page 41: ...41 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 1000 SCFM AIR COOLED...
Page 43: ...43 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 150 200 SCFM WATER COOLED...
Page 45: ...45 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 250 SCFM WATER COOLED...
Page 47: ...47 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 300 SCFM WATER COOLED...
Page 49: ...49 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 400 SCFM WATER COOLED...
Page 51: ...51 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 500 SCFM WATER COOLED...
Page 53: ...53 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 650 SCFM WATER COOLED...
Page 55: ...55 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 800 SCFM WATER COOLED...
Page 57: ...57 Replacement Part Illustration RDS Series 50 1000 SCFM Section 8 1000 SCFM WATER COOLED...
Page 63: ...63 Wiring Diagrams Air Cooled Water Cooled RDS Series 50 1000 SCFM Section 9 650 SCFM 230 3 60...
Page 69: ...69 NOTES...