Summary of Contents for 53-3498

Page 1: ...ctions Appeler la compagnie de gas imm diatement en util isant le telephone d unvoisin Suivre Lesinstructions de If you cannot reach your gas supplier call the fire la compagniede gaz department En cas d impossibilit6de joindre la compagniede gaz Installationand service must be performed by a qualified appelerles pompiers installer service agency or the gas supplier Le montage et les reparationsdo...

Page 2: ...er receptacle The wiring should be done by a qualified person in conformance with DO NOT INSTALLTHE DRYER ON A CARPETED FLOOR local codes The circuit must be protected with a 15 amp time delay fuse or circuit breaker DO NOT INSTALL OR STORE THE DRYER WHERE IT MAY BE EXPOSED TO THE WEATHER OR DRIPPING A wiring diagram is located behind backguard shield WATER If it is ever exposed to water have a qu...

Page 3: ...49 g Re install front panel over pressure tap hose requires that an acceptable approved manual gas shut h Connect the gauge turn manual valve on the supply pipe check off valve be installed within 6 feet of the dryer with dryer in operation To gain access to main gas valve remove front panel see Step SHUTDOWN INSTRUCTIONS 1 thru 3 under Bottom Exhausting Page 5 To shutdown the dryer either turn ti...

Page 4: ...GGEDTAPPING I GAS SRUT OF _H VALVE GAS INLET PIPECONNECTION GAS SUPPLY OUTSIDEWALL LINE OUTSIDEEXHAUST VENT _lb Check all connections for leaks Attach dryer vent pipe to outside exhaust vent Outside exhaust vent Coat the threads with pipe seal com pound then connect the gas supply ALL GAS DRYERS MUST BE should fit over dryer vent pipe to avoid line to the gas inlet on the dryer VENTED TO THE OUTDO...

Page 5: ...hould face away from the dryer Do not use screws or other fasteners that extend into the exhaust pipe or duct Flexible 4 diameter metal tubing may be used for exhausting the dryer However the convolutions create a greater restric tion than pipe and serious blockage can result if the tubing is 3 Remove front panel by removing two 1 4 screws inside top bent too sharply If clearance to the wall is le...

Page 6: ...freely to the outside atmosphere with the termination securely 15 Position cylinder belt with grooved side around motor fastened to the mobile home structure and which is fab pulley Pull idler pulley right until smooth side of belt can ricated of a material that will not support combustion be routed around left side of idler pulley FIG 3 Standard four inch diameter galvanized or aluminum pipe shou...