![Gardner Denver L55 User And Service Manual Download Page 58](http://html1.mh-extra.com/html/gardner-denver/l55/l55_user-and-service-manual_3819987058.webp)
56
August 20, 2018
12
Annex
12.1 Technical specifications
12.1.1 USA/CANADA version L55-
L80
A - air cooled
Technical data 60 Hz
L55
L75
L80
Nominal pressure
psi g
100
125
190
100
125
190
100
125
Maximum operating pressure
psi g
110
130
190
110
130
190
110
130
Minimum operating pressure
psi g
75
Ambient temperature -min / max
°F
34...113
FAD at nominal pressure
cfm
380.80
350.80
289.9
474.40 444.10 371.5 514.20 467.8
Outlet temperature of air above ambient
°F
11
13
Free field noise level (ISO 2151)
dB(A)
73
75
72
Nominal motor rating
hp (kW)
75 (55)
100 (75)
Full load current max. IP55
(200V , 230V, 460V, 575V)
Amps
255 / 223 / 112 / 88
371 / 323 / 162 / 130
Motor protection type
-
TEFC IP55, EPACT
Drive motor speed
rpm
3600
Fan motor power
hp (kW)
1.9 (1.4)
3.4 (2.5)
Suggested cable size
(200V , 230V, 460V, 575V) at 167°F
AWG2/0
AWG1/0
AWG1
AWG2
MCM250
AWG4/0
AWG3/0
AWG1/0
Suggested fuse rating (slow-blow fuse, class
J)
(200V , 230V, 460V, 575V)
Amps
150 / 150 / 125 / 90
225 / 200 / 175 / 150
Ventilating fan capacity
cfm
4308
6003
Cooling air temp above ambient temp. approx.
°F
45
45
Max. allowable pressure drop in duct at
ambient
Pa
90 / 50
110 / 70
Compressor oil capacity
gal (l)
9 (34)
Compressed air delivery connection
(male screwed thread)
-
2 - 11 1/2 NPT
Weight
lbs (kg)
3803 (1725)
3891 (1765)
4431 (2010)
Package dimensions L x W x H
in/mm
85 x 48.1 x 77.6 (2158 x 1223 x 1971)