C.  Piping

1.  Before installing, blow out pipe line to remove scale 

and other foreign matter.  

2.  This unit has DRYSEAL pipe threads; use pipe com

-

pound or tape sparingly to male threads only. 

3.  Mounting (Grades A, B, C, D, E, F) - mount so that 

inlet and outlet connections are horizontal (filter bowl 

vertical) to ensure proper liquid drainage.

4.  Flow Direction - install so that the air flow is in the 

direction of arrows on the filter head.  
NOTE:  Grade D flows from outside to inside of 

element.  All other grades flow from inside to outside 

of element.  Observe flow arrows on cap.

5.  Direct filter-to-filter (modular) connection - Filter 

heads may be joined without using a pipe nipple
a.  Bayonet type heads - Use two (2) modular 

connectors, o-ring, and four (4) socket head cap 

screws (sold as kit). 
Remove black plastic top cap, apply generous 

amount of lubricant to o-ring, install o-ring in 

groove, and insert connectors.  Screw connectors 

to head using socket head cap screws.

b.  Threaded heads

Use four carriage bolts, nuts and o-ring (sold 

as kit).   Remove black plastic top caps, apply 

generous amount of lubricant to o-ring, install 

o-ring in groove, and install bolts and nuts.

NOTE: Make certain flow direction through filters is 

correct (observe pin hole used for aligning top caps).  

Grades A, B, C, E, F, G - when hole is on side closest to 

you, inlet is to left.  Grade D - when hole is on the side 

farther from you, inlet is to left.

NOTE:  Lubricate o-ring with generous amount of 

lubricant before installation.
6.  Isolation valves and by-pass piping - For ease of 

service, isolation and by-pass valves are desirable.  In 

critical applications, two filters installed in parallel may 

be necessary to avoid interruption of air supply.

D.  Drain provisions

1.  Internal Automatic Drains - Drain line

The bottom of internal automatic drains are provided 

with 1/8" (inside threads) for connection of a drain 

line if desired.

2.  External Auto Drains - External auto drains may be 

added as follows: 
Models 12 through 20 - remove internal drain and 

install adapter (available from factory).  Adapter outlet 

connection is  1/8" (inside threads). 

  

Discharge is at system pressure; anchor 

drain line.
Models 22 through 30 - Remove adapter fitting from 

bottom of bowl; 1/2" (inside threads) port is available 

for external drain connection.

Summary of Contents for FIL Series

Page 1: ...ard 1910 134 for breathing air requirements 3 Flammable devices While the materials of construction are compatible with many flammable gases the following application limitations must be considered Ho...

Page 2: ...indicated in space 4 D Internal Automatic Drain Mechanism P Differential Pressure Slide Indicator G Differential Pressure Gauge Indicator L Liquid Level Indicator S Corrosion Proof Stainless Steel El...

Page 3: ...il removal at point of use 0 01 99 99 of oil 1 000 aerosols 0 008 aerosols F Prefilter ahead of desiccant and membrane dryers use after Grade C to reduce liquid and solids load prolong element life an...

Page 4: ...black plastic top caps apply generous amount of lubricant to o ring install o ring in groove and install bolts and nuts NOTE Make certain flow direction through filters is correct observe pin hole us...

Page 5: ...his might indicate a Possible leak across element o ring seal b Leak through the element due to physical damage Grades A B C E F 1 Check to see that filter is installed level to insure proper drainage...

Page 6: ...t rated capacity Element life is exhausted when odor can be detected downstream of the filter B Procedure for Element Replacement THIS FILTER IS A PRESSURE CONTAINING DEVICE DEPRESSURIZE BEFORE SERVIC...

Page 7: ...2 132 6 3 2 9 6 9 3 1 10 2 4 63 11 3 5 13 28 12 70 33 14 97 38 17 24 Maximum Working Pressure Housing 300 psig 21 1 kgf cm 2 Models with Internal Drain or Liquid level indicator 250 psig 17 6 kgf cm...

Page 8: ...yer of the manufacturer s product The maximum damages liability of the manufacturer is the original purchase price of the product or part THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER W...