1.0 Installation

A.  Where Used/Air Quality After Filtration

Grade

Where used

Solid particle 

removal (maximum 

size in  microns)

Liquid removal 

efficiency (at rated 

conditions)

Maximum inlet liquid 

loading ppm w/w

Remaining oil 

content ppm w/w

A

Separator - downstream of an aftercooler

Point-of-use - where no aftercooler is 

installed upstream

95% of water

30,000

bulk liquids

B

Separator - downstream of an aftercooler

Point-of-use - where no aftercooler 

is installed upstream or as prefilter to 

refrigerated dryer

3

99+% of water

25,000 

aerosols & bulk liquids

5

aerosols

C

Prefilter -

•  Prefilter to Grade F & Grade E high     

efficiency filters

•  Point-of-use - where aftercooler is 

installed upstream 

1

100% of water

2, 000

aerosols

1

aerosols

D

Afterfilter - downstream of a pressure-swing 

(heatless) desiccant dryer

Downstream of an Activated Carbon or 

Desiccant Tower

1

No liquid should be 

present at inlet

No liquid should be 

present at inlet

E

Prefilter - ahead of desiccant and membrane 

dryers

Afterfilter 

•  Downstream of refrigerated dryer

•   Downstream of pressure-swing 

(heatless)  desiccant dryers for finer 

solid particle removal

•  Oil removal at point-of-use

0.01

99.99+% of oil

1, 000

aerosols

0.008

aerosols

F

Prefilter - ahead of desiccant and membrane 

dryers (use after Grade C to reduce liquid 

and solids load, prolong element life and 

ensure filtration efficiency)

Afterfilter  -  downstream of refrigerated 

dryer

0.01

99.999+% of oil

100

aerosols

0.0008

aerosols

G

Afterfilter to Grade E & Grade F for true  oil 

free applications

0.01

Removes vapors only

No liquid should be 

present

0.003 

vapor

Wall Mounting 
Bracket

Top Cap

Figure 1.1

B.  Mounting

1.  Wall mounting brackets - Mount bracket to filter 

head: 
(1)  remove four (4) screws holding black plastic top 

cap to filter head

(2)  place bracket on head over plastic cap
(3)  install screws supplied with bracket.

2.  Differential Pressure Gauge Mounting to Filter head 

(1)  make certain o-rings are in place on the bottom 

of the gauge body.

(2)  connect the low pressure transmission bolt (bolt 

next to the RED band on gauge) to the gauge 

port at the filter outlet (downstream side of 

filter).

(3)  connect the high pressure transmission bolt (bolt 

next to GREEN band on gauge) to the gauge port 

at the filter inlet (upstream side of the filter). 

(4)  use a coin or a flat head screwdriver to tighten/

loosen bolts. The tip width of the screwdriver 

should be at least 3/8" inch (9.5 mm). Torque 

bolts to 25 +/-5 inch oz. 

DO NOT OVER TIGHTEN.

Summary of Contents for FIL Series

Page 1: ...ard 1910 134 for breathing air requirements 3 Flammable devices While the materials of construction are compatible with many flammable gases the following application limitations must be considered Ho...

Page 2: ...indicated in space 4 D Internal Automatic Drain Mechanism P Differential Pressure Slide Indicator G Differential Pressure Gauge Indicator L Liquid Level Indicator S Corrosion Proof Stainless Steel El...

Page 3: ...il removal at point of use 0 01 99 99 of oil 1 000 aerosols 0 008 aerosols F Prefilter ahead of desiccant and membrane dryers use after Grade C to reduce liquid and solids load prolong element life an...

Page 4: ...black plastic top caps apply generous amount of lubricant to o ring install o ring in groove and install bolts and nuts NOTE Make certain flow direction through filters is correct observe pin hole us...

Page 5: ...his might indicate a Possible leak across element o ring seal b Leak through the element due to physical damage Grades A B C E F 1 Check to see that filter is installed level to insure proper drainage...

Page 6: ...t rated capacity Element life is exhausted when odor can be detected downstream of the filter B Procedure for Element Replacement THIS FILTER IS A PRESSURE CONTAINING DEVICE DEPRESSURIZE BEFORE SERVIC...

Page 7: ...2 132 6 3 2 9 6 9 3 1 10 2 4 63 11 3 5 13 28 12 70 33 14 97 38 17 24 Maximum Working Pressure Housing 300 psig 21 1 kgf cm 2 Models with Internal Drain or Liquid level indicator 250 psig 17 6 kgf cm...

Page 8: ...yer of the manufacturer s product The maximum damages liability of the manufacturer is the original purchase price of the product or part THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER W...

Reviews: