3
1.0 Installation
A. Where Used/Air Quality After Filtration
Grade
Where used
Solid particle
removal (maximum
size in microns)
Liquid removal
efficiency (at rated
conditions)
Maximum inlet liquid
loading ppm w/w
Remaining oil
content ppm w/w
A
Separator - downstream of an aftercooler
Point-of-use - where no aftercooler is
installed upstream
—
95% of water
30,000
bulk liquids
—
B
Separator - downstream of an aftercooler
Point-of-use - where no aftercooler
is installed upstream or as prefilter to
refrigerated dryer
3
99+% of water
25,000
aerosols & bulk liquids
5
aerosols
C
Prefilter -
• Prefilter to Grade F & Grade E high
efficiency filters
• Point-of-use - where aftercooler is
installed upstream
1
100% of water
2, 000
aerosols
1
aerosols
D
Afterfilter - downstream of a pressure-swing
(heatless) desiccant dryer
Downstream of an Activated Carbon or
Desiccant Tower
1
No liquid should be
present at inlet
No liquid should be
present at inlet
—
E
Prefilter - ahead of desiccant and membrane
dryers
Afterfilter
• Downstream of refrigerated dryer
• Downstream of pressure-swing
(heatless) desiccant dryers for finer
solid particle removal
• Oil removal at point-of-use
0.01
99.99+% of oil
1, 000
aerosols
0.008
aerosols
F
Prefilter - ahead of desiccant and membrane
dryers (use after Grade C to reduce liquid
and solids load, prolong element life and
ensure filtration efficiency)
Afterfilter - downstream of refrigerated
dryer
0.01
99.999+% of oil
100
aerosols
0.0008
aerosols
G
Afterfilter to Grade E & Grade F for true oil
free applications
0.01
Removes vapors only
No liquid should be
present
0.003
vapor
Wall Mounting
Bracket
Top Cap
Figure 1.1
B. Mounting
1. Wall mounting brackets - Mount bracket to filter
head:
(1) remove four (4) screws holding black plastic top
cap to filter head
(2) place bracket on head over plastic cap
(3) install screws supplied with bracket.
2. Differential Pressure Gauge Mounting to Filter head
(1) make certain o-rings are in place on the bottom
of the gauge body.
(2) connect the low pressure transmission bolt (bolt
next to the RED band on gauge) to the gauge
port at the filter outlet (downstream side of
filter).
(3) connect the high pressure transmission bolt (bolt
next to GREEN band on gauge) to the gauge port
at the filter inlet (upstream side of the filter).
(4) use a coin or a flat head screwdriver to tighten/
loosen bolts. The tip width of the screwdriver
should be at least 3/8" inch (9.5 mm). Torque
bolts to 25 +/-5 inch oz.
DO NOT OVER TIGHTEN.