13-25-600 Page 33
1. Open, lockout and tagout the main disconnect and any other circuits before doing any conversion
work on the compressor package.
2. All fuses, decals and voltage markers are supplied in conversion kit 304ELA6005.
3. Open the compressor electrical control panel. Locate the control transformer (CT) as shown on
the applicable wiring diagram (see wiring diagram attachments).
4. Remove the transformer primary wiring connection (wire 1L1) from the transformer terminal. For
a 208VAC supply voltage, reconnect wire 1L1 to the transformer primary labeled H3. For a
230VAC supply voltage, reconnect wire 1L1 to the transformer primary labeled H2. For a
460VAC supply voltage, reconnect wire 1L1 to the transformer primary labeled H1.
5. Remove the two FNQ-R fuses. For a 208VAC supply voltage, replace transformer primary fuses
with two FNQ-R-5 amp fuses (24CA2785). For a 230VAC supply voltage, replace transformer
primary fuses with two FNQ-R-5 amp fuses (24CA2785). For a 460VAC supply voltage, replace
transformer primary fuses with two FNQ-R-2-1/2 amp fuses (24CA2782).
6. Replace the fuse decal. For a 208VAC supply voltage, the fuse decal is 264AUX077. For a
230VAC supply voltage, the fuse decal is 264AUX077. For a 460VAC supply voltage, the fuse
decal is 261AUX077.
7. Install the applicable panel voltage sticker as shown in figure 1 and figure 2, below. For a
2008VAC supply voltage, install voltage sticker 69F102. For a 230VAC supply voltage, install
voltage sticker 69F103. For a 460VAC supply voltage, install voltage sticker 69F104.
8. Install the applicable panel voltage marker. For a 208VAC supply voltage, install voltage sticker
69F50. For a 230VAC supply voltage, install voltage sticker 69F51. For a 460VAC supply
voltage, install voltage sticker 69F52.
Figure 4-4 – EXAMPLE OF FACTORY 230VAC LABEL
Summary of Contents for AirSmart Controller APEX5-15A
Page 11: ...13 25 600 Page 10 Figure 1 2 COMPRESSOR ILLUSTRATION 303ELA797 B Ref Drawing Page 1 of 2...
Page 27: ...13 25 600 Page 26 Figure 4 1 CONTROL SCHEMATIC 300ELA797 B Ref Drawing...
Page 37: ...13 25 600 Page 36 300ELA546 B Ref Drawing Page 2 of 2...
Page 39: ...13 25 600 Page 38 301ELA546 B Ref Drawing Page 2 of 2...
Page 41: ...13 25 600 Page 40 304ELA546 B Ref Drawing Page 2 of 2...
Page 43: ...13 25 600 Page 42 305ELA546 B Ref Drawing Page 2 of 2...
Page 45: ...13 25 600 Page 44 309ELA546 B Ref Drawing Page 2 of 2...