13-25-600 Page 47
Improper equipment maintenance with use of synthetic lubricants will damage
equipment. Oil filter and oil separator change intervals remain the same as for
AEON 4000 – See “Maintenance Schedule”, page 64.
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
Compressor, air/oil reservoir, separator chamber and all piping and tubing may
be at high temperature during and after operation.
High temperature operation can cause damage to equipment or personal injury.
Do not repeatedly restart the unit after high temperature stops operation. Find
and correct the malfunction before resuming operation.
All materials used in Gardner Denver compressor units are compatible with
AEON 9000SP Lubricant. Use caution when selecting downstream components
such as air line lubricating bowls, gaskets and valve trim.
AEON 9000SP Synthetic Lubricant is not compatible with low nitrile Buna N or
acrylic paints. AEON 9000SP is compatible with most air system downstream
components.
Safety Data Sheets (SDS) are available for all AEON lubricants at web address.
www.gardnerdenverproducts.com/downloads.aspx
Summary of Contents for AirSmart Controller APEX5-15A
Page 11: ...13 25 600 Page 10 Figure 1 2 COMPRESSOR ILLUSTRATION 303ELA797 B Ref Drawing Page 1 of 2...
Page 27: ...13 25 600 Page 26 Figure 4 1 CONTROL SCHEMATIC 300ELA797 B Ref Drawing...
Page 37: ...13 25 600 Page 36 300ELA546 B Ref Drawing Page 2 of 2...
Page 39: ...13 25 600 Page 38 301ELA546 B Ref Drawing Page 2 of 2...
Page 41: ...13 25 600 Page 40 304ELA546 B Ref Drawing Page 2 of 2...
Page 43: ...13 25 600 Page 42 305ELA546 B Ref Drawing Page 2 of 2...
Page 45: ...13 25 600 Page 44 309ELA546 B Ref Drawing Page 2 of 2...