21
GB
Fault Possible
Cause
Remedy
The water is not clear
Too many fish and creatures
v
Add up the estimated
in the pond.
length of the fish.
There should only be “80 cm
length of fish fish” per m
3
water
in the pond.
The glass tube of the UVC unit
v
Clean UVC unit
is dirty.
(see 7. Maintenance).
The flow is reduced
The filter sponges are dirty.
v
Clean filter
(see 7. Maintenance).
Pump filter housing is dirty.
v
Clean pump filter housing.
Rotor unit is blocked.
v
Clean pump.
he UVC pilot light is not on
Bulb defective.
v
Change bulb.
Electrical connections defective.
v
Check electrical
connections.
ATTENTION !
Repairs on electrical parts should only be carried out by
GARDENA Service Centres or an authorised repairer.
If any other faults arise, please contact GARDENA Service.
9. Accessories
GARDENA
1
”
-Hose (for use as inflow
Art. 7831
Ribbed pond hoses
or outflow hose)
10. Technical Data
PF 10000 S (Art. 7872)
PF 15000 S (Art. 7873)
Rated power, UVC unit
7 W
11 W
Power cable, UVC unit
3 m H05 RN-F 3G0,75
3 m H05 RN-F 3G0,75
Bulb, UVC unit
type 7 W TC-S (UV-C)
type 11W TC-S (UV-C)
(e.g. Radium: Puritec (e.g. Radium: Puritec
NSE 7-270, Philips: TUV
NSE 11-270, Philips: TUV
PL-S 7 W or Sylvania:
PL-S 11 W or Sylvania:
G7 LYNX-S Germicidal)
G11 LYNX-S Germicidal)
Rated power, pump
25 W
40 W
Power cable, pump
10 m H05 RN-F 3G0,75
10 m H05 RN-F 3G0,75
Max. delivery capacity, pump
1,500 l / h
2,500 l / h
Max. delivery head, pump
1.9 m
2.2 m
Max. operating pressure
0.19 bar
0.22
Mains voltage /
mains frequency
230 V / 50 Hz
230 V / 50 Hz
Max. immersion depth
2 m
2 m
Media temperature
4 °C – 35 °C
4 °C – 35 °C