18
GB
Overwintering /
Storage :
We recommend that you lay the return flow in such a way that
the purified water is reintroduced indirectly e.g. via a short
stream. This enriches the purified water with additional oxygen.
6. Putting out of Operation
1. Before frost, remove the pump from the pond, remove the hose
from the pump and fully empty the UVC pressure filter.
2. Clean the UVC pressure filter thoroughly (see
7. Maintenance
“ Removing fine dirt”
) and allow to dry.
3. Immerse the pump
(without mains plug)
completely in a
container filled with water.
4. Position the UVC pressure filter and pump in a place protected
from frost, and ensure that the mains plug of the UVC device
and pump are protected from moisture.
Store out of reach of children.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
7. Maintenance
DANGER ! Electric shock !
A
v
v
Before undertaking maintenance, unplug the
UVC-unit and the pump from the mains !
WARNING ! Danger of the container bursting !
A
v
v
Do not connect the pressure filter to the
domestic water supply !
Dirt indicator visible
Dirt indicator not visible
.
Flow
.
No / insufficient flow
.
Filter function O.K.
.
Filter soiled
If the dirt indicator is not fully visible during operation indicating
a low flow, the pressure filter must be cleaned. The mechanical
cleaning equipment simplifies the cleaning process.
1. Exchange the connecting hose
1
and return hose
C
and
guide the return hose
C
to the desired position.
2. Connect the pump to the power supply.
3. Pull the cleaning handle
G
several times during operation
and hold briefly. The filter sponges are squeezed and the
dirt washed out.
4. If the water from the return hose
C
is clear, switch off the pump.
5. Exchange the connecting hose
1
and return hose
C
again
and guide the return hose
C
back into the stream or pond.
Return flow tip :
Removal of severe soiling :
Disposal :
(in accordance with
RL 2002 / 96 / EC)
G
1
G
C