background image

17

GB

1. Push a threaded ring 

7

over both universal connectors 

5

and 

6

.

2. Screw the transparent universal 

connector 

5

with dirt indicator 

8

onto the water outlet 

9

(see 

arrow markings on the cover).
Pay attention to the installation 
position of the dirt indicator 

8

.

3. Screw the black universal 

connector 

6

with flat seal 

0

onto the water inlet 

A

.

4. Push one hose clamp 

B

onto the connecting hose 

1

and 

one on the return hose 

C

.

5. Push the connecting hose 

1

on the black universal 

connector 

6

and secure with the hose clamp 

B

.

6. Push the return hose 

C

onto the transparent universal 

connector 

5

and secure with the hose clamp 

B

.

For safety reasons, the UVC lamp is supplied unassembled.

v

Assembling the lamp in the UVC device: (see 

8. Trouble-

Shooting

“ Replacing lamp”

).

5. Initial Operation 

If the pressure filter is buried below the surface, the hose
connectors must be located above the surface of the pond.
When using a stream, the maximum height must not be 
exceeded.

1. Bury or position the pressure filter 

D

securely at least 2 m

away, next to the garden pond and above the surface of the
pond (max. 1 m with PF 10000 or 1.5 m with PF 15000).

2. Place the pump 

E

in a stable position within the garden pond

so that the pump 

E

is completely covered with water.

3.

Plug the mains plug of the pump 

E

into a 230 V AC socket.

Warning : The pump will start immediately ! 

4. Remove the cover 

F

of the UVC device.

5. If the pressure filter 

D

is filled with water, connect the power

supply of the UVC device in a 230 V alternating current socket.

The UVC control lamp is lit blue (more visible at dusk / in 
darkness).

6. Replace the cover 

F

of the UVC device.

Switch off the UVC Pressure Filter Set :

1. First, disconnect the UVC device from the power supply.

2. Then disconnect the pump from the power supply.

PF 10000 = 1 m
PF 15000 = 1,5 m

D

F

E

Connecting the hoses to the
pressure filter :

Assembling the lamp in the
UVC device :

Operating the UVC-Pressure
Filter Set :

8

8

5

7

9

0 6

A

5

C

6

1

B

Summary of Contents for PF 10000 S

Page 1: ...iltre pression UVC NL Instructies voor gebruik UVC drukfilterset S Bruksanvisning UVC tryckfilterset I Istruzioni per l uso Set filtro a pressione UVC E Manual de instrucciones Juego de filtros a pres...

Page 2: ...Range of Uses forYour GARDENA UVC Pressure Filter Set The UVC Pressure Filter Set is intended for private use in domestic gardens and allotments and should only be used out of doors for cleaning gard...

Page 3: ...t When newly installed the UVC Pressure Filter Set only reaches its full biological cleaning effect after a few weeks Extensive bacteria activity only takes place from a temperature of 10 C or above H...

Page 4: ...ansformer v Please contact your electrician For Switzerland In Switzerland mobile appliances which are used outdoors must be connected via a residual current device Note Operation of the pressure filt...

Page 5: ...s This promotes the growth of micro organisms which guarantee the conversion of ammonia into nitrate via nitrite nitrification Lava stone This supports the growth of anaerobic micro organisms which pr...

Page 6: ...the surface of the pond When using a stream the maximum height must not be exceeded 1 Bury or position the pressure filter D securely at least 2 m away next to the garden pond and above the surface of...

Page 7: ...nce DANGER Electric shock A v v Before undertaking maintenance unplug the UVC unit and the pump from the mains WARNING Danger of the container bursting A v v Do not connect the pressure filter to the...

Page 8: ...ing water 7 Assemble the pressure filter again in reverse order Ensure that the O Ring O is sitting correctly 8 Start operation of the pressure filter again see 5 Initial Operation Operating the UVC P...

Page 9: ...he UVC unit in reverse order DANGER Short circuit A v v The ring U must be screwed on firmly again to guarantee that the glass tube T is sealed During assembly ensure that the O Ring X on the glass tu...

Page 10: ...res or an authorised repairer If any other faults arise please contact GARDENA Service 9 Accessories GARDENA 1 Hose for use as inflow Art 7831 Ribbed pond hoses or outflow hose 10 Technical Data PF 10...

Page 11: ...d in keeping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit The wearing parts UVC bulb filter materials and...

Page 12: ...n om skadan beror p att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra n Original GARDENA reservdelar har anv nts Samma sak g ller f r kompletteringsdelar och tillbeh r...

Page 13: ...urit et autres r gles qui lui sont applicables dans le cadre de l Union europ enne Toute modification port e sur ce produit sans l accord express de GARDENA supprime la validit de ce certificat N EU o...

Page 14: ...di rendimento Curva caracter stica de la bomba Caracter sticas de performance Ydelses karakteristika PF 10000 S Art 7872 Pumpen Kennlinie Performance characteristics Courbes de performance Prestatieg...

Page 15: ...k ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info gardenaitalia it Japan K...

Reviews: