background image

GARDENA Garden Pump 5600 Art. 9057

Max. 1.3 bar

GARDENA Garden Pump 6300 Art. 9058

Max. 1.1 bar

The pump Art. 9059 must not be used for pressure amplification because 

the pump delivers 6 bar.

1.3.2 Additional electrical safety warnings

 DANGER!

Risk of cardiac arrest!

This product generates an electromagnetic field while it operates. This electro-

magnetic field may affect the functionality of active or passive medical implants 

(e. g. pacemakers), which may result in serious injury or death.

v

 Consult your doctor and the manufacturer of your implant before using this 

product.

v

  After using the product, disconnect the mains plug from the mains socket.

The pump must be installed in a stable and flood-proof location and protected 

against falling into the water. Take care that the pump cannot fall into water. 

 Position the pump at a safe distance (min. 2 m) from the liquid to be pumped.  

As an additional safety device an authorised safety switch can be used.

v

  Ask your electrician for his advice.

The pump’s mains plug must be disconnected before anybody enters the 

 swimming  pool.
If the supply cord is damaged, it must be replaced by the manufacturer, its 

 service agent or similarly qualified persons in order to avoid a hazard. 

v

  Protect the mains plug and the mains power cable from heat, oil and sharp 

edges.

v

  Do not use the power cable for carrying the pump or for unplugging.

v

  Place the pump in a flood-proof location.

v

  Please regularly check the connecting line.

v

  Before using, always subject the pump (especially the power cables and  

the power connections) to a visual inspection.
A pump which is damaged must not be used.

v

  In the event of damage, have the pump checked by GARDENA Service.

Electrical changes are only conducted by an electrical specialist.

v

  Before filling, dismantling, maintenance disconnect the mains.

v

  When using our pumps with a generator, the warnings of the generator 

 manufacturer must be observed.

1.3.2.1 Cables:
If extension cables are used, these must comply with the minimum cross-sections 

in the table below:
Voltage

Cable length

Cross section

230 – 240 V / 50 Hz

Up to 20 m

1.5 mm²

230 – 240 V / 50 Hz

20 – 50 m

2.5 mm²

1.3.3 Additional personal safety warnings

 

DANGER!

Risk of suffocation!

Small parts can be easily swallowed. 

Keep toddlers away when you assemble the product.

 

DANGER!

Risk of injury from hot water!

Pumped water is under pressure and when it hits the body or eyes 

 directly can cause injury.
If the pump is operated for prolonged periods of time (> 5 min.) with the 

delivery side closed, the water in the pump may heat up so that there is 

a risk of scalding yourself with hot water.

Let the pump operate for max. 5 minutes against the closed pressure 

side or with missing water supply.
If the water supply on the intake side of the pump fails, the water in the 

pump can heat up so that if water emerges, injuries could be caused by 

the hot water.

Disconnect the pump from the mains and let the water cool.

Do not open any caps and screw connections when the water is hot.

Before restarting, secure the water supply on the suction side and fill 

the pump completely with water.
If hoses or pipes are exposed to the sun, they can become very hot.

When connecting the pump to the water supply system, the country-specific 

 sanitary regulations must be observed to prevent water not of drinking water 

quality being drawn back in.

v

  Consult a specialist for sanitary installations.

In order to avoid dry-running of the pump, take care that the end of the suction 

hose is always submerged into the liquid.

v

  Before each operation, fill the pump with water up to the overflow (min. 2 l)!

v

  When filling the pump with water, make sure that no hoses or consumers are 

connected to the pump and that the pump is generally in a horizontal position.

v

  Make sure that the hoses are laid without kinks.

Sand and other abrasive substances cause increased wear and reduce the 

pump’s output.

v

  Use the pump only with the integrated filter installed.  

Otherwise the pump could be damaged.

v

  Use a pump pre-filter for pumping sandy liquids.

Pumping dirty water, e. g. stones, pine needles etc., can cause damage to the 

pump.

  Do not pump dirty water.

The minimum flow rate is 90 l/h (1.5 l/min). Connection devices with a lower flow 

rate must not be operated.

2. ASSEMBLY

 DANGER!

Risk of injury!

Risk of injury due to accidental starting.

 Unplug the plug of the mains cable from the mains socket.

2.1 Installation site:

• When installing below the water level, a shut-off device must be

installed to prevent unwanted water loss.

• The installation site must be horizontal, solid and dry and allow the

pump to stand securely.

• It must be at a distance of at least 2 m from the water.
• The pump must be installed in a flood-proof location.

2.2 To connect the hose to the suction side [ Fig. A6 ]:

The connector on the suction side 

(1)

 is equipped with a 33.3 mm (G 1") 

external thread.
The connection piece on the suction side may only be tightened  

by hand [ Fig. A2 ].
In order to reduce the suction time, it is advisable to use a suction hose 

with backflow preventer avoiding automatic draining of the suction hose 

when the pump has been switched off [ Fig. A3 ].
Sucking in air in the suction system can lead to functional failure and 

increased noise generation.

v

  Connect the suction system carefully.

v

  Check the gasket regularly and replace it if necessary.

Don’t use any hose quick connection system fittings on the suction  

side.
A vacuum-resistant suction hose must be used on the suction side:
•  e. g.  the  GARDENA Suction Unit Art.  1411 / 1412 / 1418
• or the GARDENA Bore Hole Suction Hose Art. 1729.
• Connect suction hoses 

(2)

 without threaded connection via a suction

hose connection piece (e. g. Art.  1723 / 1724) to the connection of the

suction side and screw it airtight.

2.2.1 There are 2 types of connection systems:

Intended for flat gasket:
No thread sealing tape is required.

v

  Make sure that the flat gasket 

ß

G

 is inserted in the suction hose 

 connection piece and is undamaged.

Intended for thread sealing tape (Teflon):
No flat gasket is required.
An unsuitable sealing system can lead to leaks.

v

  Use the sealing system intended for this purpose.

1. Make sure that the flat gasket 

ß

G

 is inserted in the suction hose con-

nection piece.

2. Screw the vacuum-resistant suction hose 

(2)

 airtight on the connector

on the suction side 

(1)

. The connection piece must be placed straight

on  [ Fig.  A1 ].

3. Lay the suction hose 

(2)

 straight and free of twists.

4. For suction heights exceeding 3 m: Fix the suction hose 

(2)

 additionally.

(e.g. by fastening it to a wooden post). 

Therefore, the pump is relieved of the weight of the suction hose.

en

10

Summary of Contents for 5600 Silent+

Page 1: ...en Operator s manual Garden pump 5600 Silent Art 9057 6300 SilentComfort Art 9058 6500 SilentComfort Art 9059 en...

Page 2: ...2 A1 A2 M A X A3 Art 1411 Art 1418 BACKFLOW A4 FULL ON ON min 2 l A5...

Page 3: ...3 A6 Art 1723 Art 1724 1 2 G A7 4 3 3a G A8 c z O1 min 2 l 6 5 O2 min 1 8 m 4 7 S1 Art 9057 Art 9058 9059 4 5 6 8 8 T1 c q 0 0 9c 9a 9b T3 e r 5 e r 6 1 2 T4 z z t T2 0 0 c w...

Page 4: ...dditional safety warnings 1 3 1 Intended use This product may be used under supervision or if instruction regarding the safe use of the product has been provided and the resulting dangers have been un...

Page 5: ...ecting the pump to the water supply system the country specific sanitary regulations must be observed to prevent water not of drinking water quality being drawn back in v Consult a specialist for sani...

Page 6: ...e GARDENA Garden Pump Bluetooth can be controlled at any time with the free GARDENA Bluetooth App It can be downloaded from the Apple App Store or from the Google Play Store v See the enclosed instruc...

Page 7: ...Tilt the pump in the direction of the drain approx 80 so that the pump empties completely 6 Unscrew the suction hose and the pressure hose 7 Tighten the screw connection 5 on the filling opening 6 and...

Page 8: ...the water Fig A5 v Submerge the end of the suction hose deeper in the water Suction filter or backflow preventer in the suction hose are clogged v Clean the suction filter or the back flow preventer N...

Page 9: ...1 Disposal of the pump according to Directive 2012 19 EU The product must not be disposed of to normal household waste It must be disposed of in line with local environmental regulations IMPORTANT v D...

Page 10: ...stics Courbes de performance Prestatiegrafiek Kapacitetskurva Ydelses karakteristika Pumpun ominaisk yr Pumpekarakteristikk Curva di rendimento Curva caracter stica de la bomba Caracter sticas de perf...

Page 11: ...14 53 UE O texto na ntegra da declara o de conformidade UE est dispon vel no seguinte endere o na Internet http www gardena com int support safety regulations pl Deklaracja zgodno ci UE dla art 9058 9...

Page 12: ...hindamismenetlus vastavalt 2000 14 E artiklile 14 V lisa m ratase m detud garanteeritud 1 Talletatud dokumentatsioon 2 CE m rgise aasta 2022 Ulm 2022 11 01 Aiapump Tootenr fi EY vaatimustenmukaisuusva...

Page 13: ...java EU o skladnosti Spodaj podpisani kot poobla enec proizvajalca GARDENA Germany AB PO Box 7454 S 103 92 Stockholm vedska potrjuje da v nadaljevanju ozna ene naprave v izvedbi v kakr ni smo jih dali...

Page 14: ...s Stas Luxembourg Gasperich 2549 Case Postale No 12 Luxembourg 2010 Phone 352 40 14 01 api neuberg lu Malaysia Glomedic International Sdn Bhd Jalan Ruang No 30 Shah Alam Selangor 40150 Malaysia Phone...