background image

11

G

10

G

2. For Your Safety 

According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0100, submersible pumps may only be used in swimming
pools, garden ponds, and fountains if the pump is operated via a
residual-current device with a residual-current rating of 

30 mA.

The pump must not be operated 
when there are persons in the swimming pool or garden pond.

For safety reasons we recommend that you always operate 
the submersible pump via a residual-current device (DIN VDE
0100-702 and 0100-738).

v

Please contact your electrician.

In Austria, according to ÖVE B / EN 60 555 part 1 to 3, pumps
which are used in swimming pools and garden ponds, and
equipped with firm power cable should be fed via an ÖVE
approved isolating transformer – rated voltage must not exceed
230 V.

In Switzerland mobile appliances which are used outdoors, 
must be connected via a residual-current device.

According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0620, mains power cables must not have a smaller cross-
section than the rubber-sheathed cables of the designation 
H05 RNF. The cable length must be at least 10 m.

Data indicated on the type plate must match technical data of
the mains supply.

v

Take care that the electrical connections are made within dry
area, protected from flooding.

Protect plug and power cable from heat, oil and sharp edges.

v

Don’t use the power cable for plugging off.

The power cable or the float switch must not be used for mount-
ing or relocating the pump. For submerging or lifting / securing
the pump, fix a rope to the pump’s carrying handle.

Extension cables must meet the requirements of DIN VDE 0620.

v

Before operating the pump, first make a visual check, if there 
is any damage of the pump (esp. regarding power cable and
plug).

v

Observe the minimum water level and the max. delivery 
height (see 8. Technical Data).

A damaged pump must not be used.

v

In case of damage, please have the pump checked by our
GARDENA Service Centre.

During manual operation, the pump must be switched off as
soon as all the liquid has been pumped away.

v

Observe the pump at all times during manual operation.

v

Clear the outlet line before use.

Dry-running operation causes increased wear and is to be
avoided. Therefore, in manual operation the pump must be
immediately unplugged when water fails to flow.

Residual-current device 

In Austria 

In Switzerland 

Mains power 

Visual check 

Manual operation 

Notes on use 

Intended use 

Liquids to be pumped 

Please note 

GARDENA Submersible Pump 5000 S 

Welcome to the garden of GARDENA ...

Please read these operating instructions carefully and observe 
the notes given. Use the instructions to familiarise yourself with 
the submersible pump, its correct use, and the notes on safety.

For safety reasons, children under 16 as well as persons not
familiar with these operating instructions should not use this
submersible pump.

v

Keep these operating instructions in a safe place.

1. Applications Range of Your GARDENA Submersible Pump 

. . 

10

2. For Your Safety 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

11

3. Initial Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

4. Operation 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

13

5. Cleaning 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

14

6. Trouble-Shooting 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

14

7. Storage

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

15

8. Technical Data 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

15

9. Service 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

16

1. Applications Range of Your GARDENA Submersible Pump

GARDENA Submersible Pumps have been designed for private
use around your house and garden. They are predominantly desti-
nated for drainage after flooding, transfer of liquids, draining con-
tainers, taking water from wells and shafts, draining boats and
yachts as well as for water aeration and circulation for a limited
period of time.

Liquids which can be handled by the GARDENA Submersible
Pump are the following: clean and slightly contaminated water
(max. particle size 5 mm), swimming pool water (prerequisite 
is the recommended dosage of additives) and soapy water.

The pump is fully submersible (waterproof sealed) and can be
immersed in the liquid down to a depth of 9 m.

The GARDENA Submersible Pumps are not designed for
continuous operation (e.g. continuous circulating opera-
tion) in a pond. Your pump’s life will be shortened corre-
spondingly by such operation.
Corrosive, easily combustible or explosive substances 
(e.g. gasoline, petroleum, nitro thinner), fats, oils, salt-water
and waste water of toilets and urinals must not be pumped.
The temperature of the liquid handled should not exceed
35 °C.

Contents

Summary of Contents for 5000 S

Page 1: ...ubmersible Pump F Mode d emploi Pompe d évacuation pour eaux claires NL Gebruiksaanwijzing Dompelpomp S Bruksanvisning Dränkbar pump I Istruzioni per l uso Pompa sommersa E Manual de instrucciones Bomba sumergible P Instruções de utilização Bomba submersível DK Brugsanvisning Dykpumpe ...

Page 2: ...een pumped away v Observe the pump at all times during manual operation v Clear the outlet line before use Dry running operation causes increased wear and is to be avoided Therefore in manual operation the pump must be immediately unplugged when water fails to flow Residual current device In Austria In Switzerland Mains power Visual check Manual operation Notes on use Intended use Liquids to be pu...

Page 3: ... mm 1 2 hose The universal fitting 7 can also be equipped with a GARDENA Regulator Valve Art No 977 so that the contents of the out let line do not flow back through the pump after pumping The Regulator Valve can be ordered from GARDENA Service 4 Operation To ensure that the pump draws the water out the water to be drained must be at least 45 mm deep The float switch 5 turns the pump on automatica...

Page 4: ...of 35 C No power v Check fuses and electric connections Dirt particles are jammed v Disconnect plug and clean in the suction base suction base see 5 Clean ing Pump runs but output Suction base is clogged v Disconnect plug and clean suddenly decreases suction base see 5 Clean ing Attention Repairs on electrical parts should only be done by our GARDENA Service Centres If you have any problems with y...

Page 5: ... by the guar antee This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems with your pump please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet We expressly point out that in accord...

Page 6: ...est Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via Donizetti 22 20020 Lainate Mi Japan KAKUDAI Mfg Co Ltd 1 4 4 Itachibori Nishi ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No 12 Luxembourg 2010 Netherlands GARDENA Nederland B V Postbus 501...

Reviews: