background image

15

G

14

G

Flushing the Pump :

Cleaning the suction 
base and turbine :

5. Cleaning 

The pumps are virtually maintenance-free.

After having pumped chlorinated swimming pool water or other 
liquids leaving residues, the pump should be rinsed with clear
water.

Warning ! Electric shock ! 

A

Risk of injury due to electric shock.

V

Disconnect the pump from the mains before clean-
ing the suction base and turbine.

1. Unscrew the 3 Phillips screws 

8

and pull the suction base 

6

off the pump.

2. Clean the suction base 

6

and the turbine 

9

.

3. Reinstall the suction base 

6

and screw in the Phillips screws 

8

.

For safety reasons a damaged turbine 

9

can only be ex-

changed by the GARDENA Service Centre.

6. Trouble-Shooting 

Problem

Probable cause

Remedy

Pump is running,

Air cannot escape, since 

v

Open pressure line 

but doesn’t deliver.

pressure line is closed.

(e.g. kinked pressure pipe).

Air locks in the suction base.

v

Wait for max. 60 seconds 
until the pump deaerates 
automatically over the vent 
valve. If necessary, switch 
off and start it again.

Turbine clogged.

v

Disconnect plug and clean 
turbine (see 5. Cleaning).

When starting the pump, 

v

Submerge pump deeper.

water height falls below the 
min. water level.

Pump doesn’t start or 

Thermal overload switch has 

v

Disconnect plug and clean 

suddenly stops during 

switched the pump off due 

turbine (see 5. Cleaning).

operation.

to overheating.

Observe max. media temper-
ature of 35 °C.

No power.

v

Check fuses and electric 
connections.

Dirt particles are jammed 

v

Disconnect plug and clean 

in the suction base.

suction base (see 5. Clean-
ing).

Pump runs, but output 

Suction base is clogged.

v

Disconnect plug and clean 

suddenly decreases.

suction base (see 5. Clean-
ing).

Attention ! 

Repairs on electrical parts should only be done by our 
GARDENA Service Centres.

If you have any problems with your Pump, please contact our Service.

7. Storage 

Store the pump away from frost before the first frost sets in.

8. Technical Data 

Type

5000 S (Art. No. 1778) 

Rated power 

200 W

Max. delivery capacity 

5,000 l / h

Max. pressure 

0.5 bar

Max. delivery height 

5 m

Max. submersion depth 

9 m

Flat suction down to approx.

5 mm

Contaminated water with 
particle size of max.

5 mm

Power cable 

10 m H05 RNF

Pump connection 

38 mm (1 1/ 2

) / 25 mm (1

) graduated nipple, 

option GARDENA Water hose Plug-in-system 

Min. water level for operation 

45 mm 

Weight approx.

4.0 kg  

Max. media temperature

35 °C

Mains voltage /
mains frequency

230 V / 50 Hz 

Min.cut-in height  

380 mm 

Min./ max. cut-out height  

100 mm / 140 mm 

Noise level  L

WA

1)

46 dB (A) 

1) Measuring method according to EN 60335 -1 

The cut-in and cut-out height varies.

The residual water depth (draining in the flat position down 
to approx. 5 mm) is only reached during manual operation 
(see 4. Operation).

The GARDENA Submersible Pump is manufactured in accordance
with the current electrical safety regulations of the Appliance
Safety Law (GSG) and inspected by the TÜV (German institution
for technical surveillance).

Frost-free storage 

9

6

8

Cut-in / Cut-out height 

Safety and 
Approval 

Summary of Contents for 5000 S

Page 1: ...ubmersible Pump F Mode d emploi Pompe d évacuation pour eaux claires NL Gebruiksaanwijzing Dompelpomp S Bruksanvisning Dränkbar pump I Istruzioni per l uso Pompa sommersa E Manual de instrucciones Bomba sumergible P Instruções de utilização Bomba submersível DK Brugsanvisning Dykpumpe ...

Page 2: ...een pumped away v Observe the pump at all times during manual operation v Clear the outlet line before use Dry running operation causes increased wear and is to be avoided Therefore in manual operation the pump must be immediately unplugged when water fails to flow Residual current device In Austria In Switzerland Mains power Visual check Manual operation Notes on use Intended use Liquids to be pu...

Page 3: ... mm 1 2 hose The universal fitting 7 can also be equipped with a GARDENA Regulator Valve Art No 977 so that the contents of the out let line do not flow back through the pump after pumping The Regulator Valve can be ordered from GARDENA Service 4 Operation To ensure that the pump draws the water out the water to be drained must be at least 45 mm deep The float switch 5 turns the pump on automatica...

Page 4: ...of 35 C No power v Check fuses and electric connections Dirt particles are jammed v Disconnect plug and clean in the suction base suction base see 5 Clean ing Pump runs but output Suction base is clogged v Disconnect plug and clean suddenly decreases suction base see 5 Clean ing Attention Repairs on electrical parts should only be done by our GARDENA Service Centres If you have any problems with y...

Page 5: ... by the guar antee This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems with your pump please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet We expressly point out that in accord...

Page 6: ...est Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via Donizetti 22 20020 Lainate Mi Japan KAKUDAI Mfg Co Ltd 1 4 4 Itachibori Nishi ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No 12 Luxembourg 2010 Netherlands GARDENA Nederland B V Postbus 501...

Reviews: