background image

13

G

12

G

Avoid running of the pump for more than 10 min. against closed
delivery side of the pump.

Sand and other abrasive substances cause increased wear and
reduce the pump’s output.

Take care that the pump is located where the inlet openings at
the suction base are obstructed neither completely nor partly.

Stand the pump on a brick if using in a pond.

The pump is automatically switched off on overheating by 
the built-in thermal motor protector. After having cooled down, 
the motor automatically switches on again (see 6. Trouble
Shooting).

The automatic deaerating valve eliminates any air pockets in 
the pump. If the water level drops below the vent valve, some
water flows penetrates outside through the vent valve 

4

.

This is not a defect of your pump, but serves to deaerate the
pump.

Thermal motor protector 

Automatic deaerating 
valve

3. Initial Operation 

13 mm (1/ 2

)

Hose diameter 

15 mm (5 / 8

)

25 mm (1

)

38 mm (1 1/ 2

)

19 mm (3 /4

)

Hose connection 
of universal fitting 

7

Hose connection 

Cut off topmost 

Do not cut off 

Cut off top two 

nipple at

a

.

any nipples.

nipples at 

b

.

The following connection kits are required for 13 mm to 19 mm
connections:
13 mm (1/ 2

):

GARDENA Pump Connection Set, Art. No. 1750

15 mm (5/ 8

):

GARDENA Tap Connector, Art. No. 902,

and 

Standard Hose Connector, Art. No. 916 

19 mm (3 /4

):

GARDENA Pump Connection Set, Art. No. 1752 

Best results in delivery capacity are achieved when using 38 mm
(1 1/ 2

) hoses.

7

a

b

The universal fitting 

7

allows you to connect all the hoses listed 

in the previous table.

1. Cut off nipples of the universal fitting 

7

, which are not needed,

to match the hose connection.

2. Screw the universal fitting 

7

onto the pump.

3. Connect the hose to the universal fitting 

7

.

We recommend that you secure 38 mm (1 1/ 2

) and 25 mm (1

)

hoses additionally with a 

GARDENA Hose Clip Art. No. 1591.

Only for 13 mm (1/ 2

) hose :

The universal fitting 

7

can also be equipped with a 

GARDENA

Regulator Valve Art. No. 977 

so that the contents of the out-

let line do not flow back through the pump after pumping.
The Regulator Valve can be ordered from GARDENA Service.

4. Operation  

To ensure that the pump draws the water out, the water to be 
drained must be at least 45 mm deep.

The float switch 

5

turns the pump on automatically when the

water level exceeds the cut-in height and the water is pumped out.

The float switch 

5

turns the pump off again as soon as the water

level falls below the cut-out height.

1. Stand the pump on a firm surface 

– or – 

use a rope attached to the carrying handle 

2

to immerse the

pump in a well or shaft.
During automatic operation, ensure that the float switch 

5

can move freely.

2. Plug the power cable 

1

into a mains socket.

Adjusting the Cut-in and Cut-out Height :

The maximum cut-in height and minimum cut-out height (see 
8. Technical Data) can be adjusted.

v

Push the cable of the float switch 

5

into the float switch lock 

3

.

Do not select a cable length that is too long or short to ensure
that the float switch can turn on and off properly.

The shorter the length of cable between the float switch 

5

and the float switch lock 

3

, the lower the cut-in height and the

higher the cut-out height.

The pump remains in constant operation because the float switch
is bypassed.

1. Stand the pump on a firm surface 

– or – 

use a rope attached to the carrying handle 

2

to immerse the

pump in a well or shaft.

2. Plug the power cable 

1

into a mains socket.

3. Fix float switch 

5

vertically above the pump (with the cable 

at the bottom).
As long as the float switch is positioned vertically above the
pump, the pump will operate regardless of the water level.

The residual water height of approx. 5 mm is only reached 
during manual operation since the float switch turns off the
pump during automatic operation before this water level is
reached.

Connecting the hose :

7

6

2

3

5

4

1

7

Automatic operation :

Manual 
operation :

2

5

1

4

Summary of Contents for 5000 S

Page 1: ...ubmersible Pump F Mode d emploi Pompe d évacuation pour eaux claires NL Gebruiksaanwijzing Dompelpomp S Bruksanvisning Dränkbar pump I Istruzioni per l uso Pompa sommersa E Manual de instrucciones Bomba sumergible P Instruções de utilização Bomba submersível DK Brugsanvisning Dykpumpe ...

Page 2: ...een pumped away v Observe the pump at all times during manual operation v Clear the outlet line before use Dry running operation causes increased wear and is to be avoided Therefore in manual operation the pump must be immediately unplugged when water fails to flow Residual current device In Austria In Switzerland Mains power Visual check Manual operation Notes on use Intended use Liquids to be pu...

Page 3: ... mm 1 2 hose The universal fitting 7 can also be equipped with a GARDENA Regulator Valve Art No 977 so that the contents of the out let line do not flow back through the pump after pumping The Regulator Valve can be ordered from GARDENA Service 4 Operation To ensure that the pump draws the water out the water to be drained must be at least 45 mm deep The float switch 5 turns the pump on automatica...

Page 4: ...of 35 C No power v Check fuses and electric connections Dirt particles are jammed v Disconnect plug and clean in the suction base suction base see 5 Clean ing Pump runs but output Suction base is clogged v Disconnect plug and clean suddenly decreases suction base see 5 Clean ing Attention Repairs on electrical parts should only be done by our GARDENA Service Centres If you have any problems with y...

Page 5: ... by the guar antee This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems with your pump please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet We expressly point out that in accord...

Page 6: ...est Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via Donizetti 22 20020 Lainate Mi Japan KAKUDAI Mfg Co Ltd 1 4 4 Itachibori Nishi ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No 12 Luxembourg 2010 Netherlands GARDENA Nederland B V Postbus 501...

Reviews: