3. Function 

1

Time

key :                   Selects date and time.

2

Channel

key :             Calls the channels.

3

Man.

key :                   Manually opens / closes individual 

                                 channels.

4

% Run-Time

key :       Calls up the % run-time function.

5

Rain Off

key :             Selects a watering break. 

6

-

keys :                  Changes data already entered. 

                                 (If you press and hold down the 

-

                                 keys you can change data in the quick 
                                 run-through mode.) 

7

OK 

key :                      Confirms the settings you selected 

                                 using the

-

keys.

8

Date and time display : 

Indicates the day of the week, date and current time. 

9

Status display : 

Indicates the current programming or watering status. 

0

% Run-Time display : 

Sets the duration of watering between 10 - 200 % for all 
channels. 

A

Key lock : 

Protects against unintentional changing of settings (the reset
function cannot be locked). 

B

Battery status display : 

When the 

Low Battery 

display flashes, the battery is almost

empty and has to be replaced. 

When the 

Low Battery

display appears, the battery is empty 

or no battery has been inserted. 

The 

Low Battery

display is re-set once the new battery has

been inserted.

The Watering Controller must be used only for controlling
commercially available 24 V (AC) valves. The electric power
consumption per channel must not exceed 600 mA
(a GARDENA Irrigation Valve Art. 1278 requires 150 mA). 

Please note

2. Safety Instructions 

Watering Controller : 

The Watering Controller must only
be operated with the 24-V (AC)
power supply unit provided.

v

Protect the 24-V (AC) power supply unit
from moisture when connected.

The Watering Controller is not splash proof. 

In order not to lose any data in the event of
power failure, an alkaline 9 V block battery
(type 6LR61) must be used for buffering data.
We recommend using batteries manufactured
by Duracell and Energizer (do not use
rechargeable batteries).

Keypad : 

Watering Controller display : 

7

1

2

3

4

5

6

8
9
B

F

E

0
A

G

C

D

Summary of Contents for 4030

Page 1: ...F Mode d emploi Programmateur NL Gebruiksaanwijzing Besproeiingscomputer S Bruksanvisning Kontrollpanel DK Brugsanvisning Vandingskontrol system FIN Brugsanvisning Kastelunohjauslaite N Brugsanvisning Vanningstimer kontrollenhet I Istruzioni per l uso Centralina E Manual de instrucciones Programación de riego P Instruções de utilização Comando de rega ...

Page 2: ... Please keep these instructions in a safe place 1 Where to Use your GARDENA Watering Controller 15 2 Safety Instructions 16 3 Function 16 4 Initial Operation 17 5 Operation 19 6 Putting Out of Operation 25 7 Trouble Shooting 25 8 Technical Data 26 9 Service Warranty 26 1 Where to Use Your GARDENA Watering Controller The Watering Controller is suitable for use indoors and in outdoor locations prote...

Page 3: ...s the battery is almost empty and has to be replaced When the Low Battery display appears the battery is empty or no battery has been inserted The Low Battery display is re set once the new battery has been inserted The Watering Controller must be used only for controlling commercially available 24 V AC valves The electric power consumption per channel must not exceed 600 mA a GARDENA Irrigation V...

Page 4: ... 24 V AC terminals only Before programming your Watering Controller install a 9 V battery to prevent loss of data if a power failure occurs 1 Release snap lock 1 and open cover 2 2 Connect the cable of the power supply unit to the 24 V AC terminals 3 Connect the cables for the valves e g 7 wire GARDENA Connection Cable Art 1280 for up to 6 valves to the terminals for the channels CHANNELS 1 and C ...

Page 5: ...ble terminals C are interconnected and equivalent to one another 4 Connect one cable of the valve V2 to the cable terminal 2 of the valve box 5 Connect the other cable of the valve V2 to a cable terminal C of the valve box Other valves can be connected similarly to V1 and V2 Connecting the Watering Controller to the Valve Box 6 Connect a cable terminal C of the Watering Controller to a cable termi...

Page 6: ...he week is selected automatically using the date When the Time key is pressed all the valves are clo sed as a precaution 1 Plug in the power supply unit or press the Time key YEAR and date year flash in the display 2 Select the date year using the keys e g 2010 and confirm by pressing the OK key MONTH and date month flash 3 Select the date month using the keys e g 05 and confirm by pressing the OK...

Page 7: ...hannel key SELECT CHANNEL and the channel flash You can end the programming mode at any time by pressing the Channel key 2 Select the channel using the keys e g channel 2 and confirm by pressing the OK key Channel appears on the display e g 2 and Select Program and the program memory location flash 3 Select the program memory location using the keys e g program memory location 3 and confirm by pre...

Page 8: ...e OK key The selected watering days e g Mo We Fr are shown on the display in frames 9 Press the Channel key and set up more watering programs The program is saved and SELECT CHANNEL and the channel flash program step 1 10 Press the Channel key The programs have been set up and the main level is displayed The main level displays the next programmed watering In this example watering on 2 Channel 2 w...

Page 9: ...nnel e g channel 2 is shown in the display If several channels are blocked Channels off is displayed If the run time is not equal to 100 the display alternates every 3 seconds between Channel off and Run Time Manual Watering Man Key The manual watering duration can be set between 0 to 59 min Channels which are already open are displayed in frames 1 Press the Man key SELECT CHANNEL and the channel ...

Page 10: ... confirmed within 10 seconds by pressing the OK key the watering begins with the watering duration displayed You can exit watering all the channels prematurely by pressing the OK key Man key for 3 seconds Percentage Watering Duration Run Time Key You can end the programming mode at any time by pressing the Run Time key The programmed watering durations of all the watering programs can be changed c...

Page 11: ...eak 1 to 9 or they can all be blocked Off in which case manual watering is still possible 1 Press the Rain Off key Rain Off and Off is displayed 2 Using the keys set the desired break e g 3 days 3 Day Delay and the frame flash 3 Confirm the break by pressing the OK key The selected break e g 3 days 3 Days Off is displayed and the programs are suspended for the break selected From 2 days onwards th...

Page 12: ...OFF The power supply unit is not v Plug the power supply unit is indicated on the display plugged in into a mains socket the programs are retained Overload The power supply is over v Only so many valves may be is indicated on the display loaded because valves from opened at the same time that the programs are retained other manufacturers have the total power consumption been used does not exceed 8...

Page 13: ...on of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet A In the event of other faults please contact GARDENA Service Repairs should only be carried out by GARDENA service centres or dealers authorised by GARDENA 8 Technical Data Power supply from power supply unit 24V AC 800 mA sufficient for 5 simultaneously open GARDENA Watering Valves Art 1278 Power ...

Reviews: