Cleaning the Integrated Filter
Always remove the mains plugs before working on the
pump.
.
Set or leave the switch on
RUN
.
.
If necessary, close the shut-off device on the inlet side of the
pump.
.
Unscrew the filter lid by turning anti-clockwise.
.
Remove the filter unit by pulling vertically upwards.
.
Hold the container and remove
the filter from the bayonet
socket by turning anti-clock-
wise.
.
Rinse the container under run-
ning water and clean the filter
using a soft brush, for example.
.
Reassemble the container-
filter unit in reverse order.
.
Insert the cleaned filter unit
into the pump.
.
Screw on the filter lid until tight.
Cleaning the Integrated Back-Flow Valve
Always remove the mains plugs
before working on the pump.
.
Set or leave the switch on
RUN
.
.
Ensure that the delivery side is de-
A
pressurised, for example, by opening
the consumers.
.
Close any shut-off devices on the inlet and
delivery side.
.
Loosen the screw by turning it anti-clockwise
until you can push the holder upwards and
backwards into opening position.
.
Remove the lid of the integrated back-flow valve by turning
anti-clockwise.
.
Remove the valve body and rinse under clean running water.
.
After cleaning, replace the valve body centrally in the correct
position (cone point downwards).
.
Screw on the lid until tight.
.
Push the holder forwards and position it in its original position.
Then tighten the screw again by turning it clockwise.