background image

13

GB

Problem

Pump runs, but the suction
action doesn’t take place.

Pump motor runs, but 
delivery capacity or 
pressure suddenly decreases.

Pump motor doesn’t start 
or suddenly stops.

If you have any other problem with your Garden Pump, please contact our Customer Service. 

Probable cause

The pump was not filled with 
the liquid to be pumped.

The liquid escapes over the 
hose which is connected to the 
delivery side during the suction 
action.

Leaky or damaged suction hose.

Absolutely vacuum-resistant connection is achieved by using 
GARDENA Suction Hoses (see point 8. Accessories).

Leaky screw fitting 

 

at the filler 

cap 

.

Air cannot escape, since delivery
side is closed or remaining water
is in the pressure hose.

The waiting time wasn’t 
observed. 

Suction filter or backflow 
preventer in the suction hose 
clogged.

Too high suction height. 

In case of any other difficulties concerning the suction action, 
use GARDENA Suction Hoses with Backflow Preventer (see point 
8. Accessories) and fill in the liquid to be pumped over the filler 
cap 

before operation.

Suction filter at the suction 
hose is sucked free.

Suction filter or backflow 
preventer clogged.

Leaks at suction side.

Impeller blocked.

No power.

Thermal overload switch has 
cut out the pump due to 
overheating/overloading. 

Electric failure.

Remedy

Fill the pump 
(see “

4. Operation

").

1. Fill the pump again 

(see “

4. Operation

"). 

2. When starting operation hold

the pressure hose approx.
1 m vertically above the
pump, until the suction action
has taken place. 

Seal the connections or check
suction hose for damages.

Tighten the screw fitting 
(do not use pliers).

Open all possible shut-off
devices (e.g. spray nozzle) in
the pressure line, or drain the
pressure hose or disconnect 
it during the suction action.

Switch on the pump and wait
max. 7 min.

Clean the filter or the back
flow preventer. 

Reduce suction height.

Reduce flow rate on the deli-
very side with a control valve,
e.g. GARDENA 

art. no. (2)977

.

Clean filter or back-flow pre-
venter. 

Eliminate leak. 

Loosen the impeller or clean
the impeller chamber.

Check fuses and electric con-
nections. 

Ensure sufficient cooling /
ventilation and clean the
impeller chamber.

Send the pump to one of our
GARDENA Service Centres.

Summary of Contents for 3000/300 Jet

Page 1: ...e de surface pour arrosage NL Gebruiksaanwijzing Beregeningspomp S Bruksanvisning Bevattningspump I Istruzioni per l uso Pompa da giardino E Manual de instrucciones Bomba para jardín P Instruções de utilização Bomba de Jardim DK Brugsanvisning Trykpumpe 3000 3 Jet Art 1442 D GB F NL S I E P DK ...

Page 2: ... for domestic use around the house and garden When using the pump for pressure intensification the max per missible internal pressure of 6 bar on the delivery side must not be exceeded The increased delivery pressure and the pump pressure have to be added together Example Pressure at the tap 1 5 bar maximum pressure of the Garden Pump 3000 3 Jet 3 3 bar total pressure 4 8 bar Liquids that can be p...

Page 3: ... not have a smaller diameter than rubber sheathed cables described with letter symbols H07 RNF Don t use the power cable for carrying the pump or for plugging off 2 For Your Safety In Austria In Austria the electrical connections must be made according to ÖVE EM 42 T2 2000 1979 22 based on 2022 Pursuant to this regulation it s imperative to operate pumps for swimming pools and garden ponds exclusi...

Page 4: ...itable for connecting 13 mm 1 2 16 mm 5 8 or 19 mm 3 4 hoses using the GARDENA hose connection system Best results regarding the delivery capacity of the pump are achie ved when connecting 19 mm 3 4 hoses in conjunction with e g GARDENA Pump Connection Set art no 1752 or when using 25 mm 1 hoses with fittings available from your sanitary dealer Connect the pressure hose to the connector on the del...

Page 5: ... that no liquid can escape from the pump via the suction hose 5 Maintenance The GARDENA Garden Pump is essentially maintenance free Cleaning your Garden Pump The pump must be cleaned after pumping chlorinated swimming pool water 1 Rinse the Garden Pump with lukewarm water max 35 C If necessary add some soft cleaning agent e g washing up liquid 2 Remove residuals according to the waste disposal law...

Page 6: ...d to be pumped over the filler cap before operation Suction filter at the suction hose is sucked free Suction filter or backflow preventer clogged Leaks at suction side Impeller blocked No power Thermal overload switch has cut out the pump due to overheating overloading Electric failure Remedy Fill the pump see 4 Operation 1 Fill the pump again see 4 Operation 2 When starting operation hold the pr...

Page 7: ... Pump Preliminary Filter sandy liquids GARDENA Electronic Automatically cuts in and out the Art no 1739 Manometric Switch pump depending on the current operating pressure With dry running safety GARDENA Prevents the pump from damages Art no 1741 Dry Running Safety in case of missing liquid GARDENA For vacuum resistant connection of Art no 1729 Bore Hole Suction Hose the pump to boreholes or pipe n...

Page 8: ...eeping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit The impeller is a wearing part and is not covered by the warranty This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If a fault occurs with your Garden Pump please return the faulty unit together ...

Page 9: ...odukten om skadan beror på att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra än Original GARDENA reservdelar har använts Samma sak gäller för kompletteringsdelar och tillbehör Responsabilità Si rende espressamente noto che conformemente alla legislazione sulla del prodotto responsabilità del prodotto non si risponde di danni causati da nostri arti coli se originati...

Page 10: ...midad de la UE El que subscribe GARDENA Kress Kastner GmbH Hans Lorenser Str 40 D 89079 Ulm declara que la presente mercancía objeto de la presente decla ración cumple con todas las normas de la UE en lo que a normas técnicas de homologación y de seguridad se refiere En caso de realizar cualquier modifi cación en la presente mercancía sin nuestra previa autorización esta declara ción pierde su val...

Page 11: ... av 0 5 m med 25 mm 1 sugslang Le prestazioni indicate nella curva di rendimento presuppongono un altezza di aspirazione pari a 0 5 m e l impiego di un tubo da 25 mm 1 Los datos de rendimiento de la curva característica de la bomba se han medido con una altura de succión de 0 5 m y con una manguera de succión de 25 mm 1 A informação técnica com as características de performance acima descritas for...

Page 12: ...8 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Japan KAKUDAI Mfg Co Ltd 1 4 4 Itachibori Nishi ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No 12 Luxembourg 2010 Netherlands GARDENA Nederland B V Post...

Reviews: