4. MAINTENANCE

  

 DANGER! Risk of physical injury!

 

  Injury when the product starts accidentally.

 Disconnect the product from the mains before 

you maintain the product.

To clean the pump:

  

 DANGER! Risk of physical injury!

 

 Risk of injury and risk of damage to the 

product.

v

  Do not clean the product with a water jet  

(in particular high-pressure water jet).

v  

Do not clean with chemicals including petrol or 

solvents. Some can destroy critical plastic parts.

v  

Clean the surface of the pump with a damp cloth.

To flush the pump:
After pumping water containing chlorine, detergents or 

heavily soiled water, the pump must be flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding 

a mild cleaning agent (e. g. detergent) until the pumped 

water runs clear.

2. Remove residuals according to the waste disposal laws 

applicable in your area.

5. STORAGE

To put into storage:
The pump is not frost-proof!
The product must be stored away from children.
1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water runs 

out.

3. Clean the pump (see 4. MAINTENANCE).
4. Store the pump in a dry, enclosed and frost-free place.

Disposal:

(in accordance with RL2012/19/EC)

 The product must not be disposed of to normal 

household waste. It must be disposed of in line 

with local environmental regulations.

IMPORTANT!

Dispose of the product through or via your municipal 

recycling collection centre.

The manual operation remains active even after discon-

necting the power supply.
To stop manual operation, disconnect the pump from the 

mains and take it out of the water. Connect the pump to 

the power supply again and keep sensor field 

ß

S9

 pressed 

until it is acknowledged by double flashing of all LEDs. 

Now you are again in automatic mode.
Only operate the manual mode under supervision.

Time-limited manual operation:
In time-limited manual operation, the sensor fields are 

deactivated for 10 minutes. The pump then runs for 

10 minutes and then switches off automatically.

v

 Keep the sensor fields 

ß

S7

 and 

ß

S8

 pushed until the 

 double flashing of all LED’s has acknowledged the 

input.  

All LEDs will light up and within 10 seconds all LEDs will 

switch off one after the other. The pump starts.

After 10 minutes the pump automatically switches back  

to automatic operation.

After disconnecting the power supply, the pump auto-

matically switches back to automatic operation.
To return to the automatic mode again, push and hold the 

2 sensor fields 

ß

S7

 and 

ß

S8

 simultaneously until the double 

flashing of all LEDs has acknowledged the input.

Flat suction / normal operation (only for the clear 

water submersible pumps) [ Fig. O2 ]:
Normal operation:
Recommended operating mode for maximum pumping 

capacity and grain size up to 5 mm, especially in automatic 

mode.

v

 Fold the 3 folding feet 

(F)

 inwards.

Flat suction:
The residual water height of approx. 1 mm is only achieved 

with flat suction in manual operation. Please note that in 

this mode the delivery and suction capacity is reduced.

v

 Fold the 3 folding feet 

(F)

 outwards.

EN

17

Summary of Contents for 11000CLEAR

Page 1: ...20000DIRT Art 9044 11000CLEAR Art 9034 17000CLEAR Art 9036 EN Operator s Manual Clear Water Submersible Pump Dirty Water Submersible Pump EN...

Page 2: ...A1 4 y A2 A3 y A4 O1 S1 S2 S3 S4 S5 S6 S7 S8 S9 A5 Art 9034 Art 9036 Art 9044 1 2 3 4 4 4a V 1 G1 1 1 G1 G1 2 1 1 T1 8 7 7 0 6 6 9 O2 3...

Page 3: ...ble for pumping the following liquids Clear Water Submersible Pump clean to slightly dirty water with a max particle size of 5 mm Dirty Water Submersible Pump dirty water with a max particle size of 3...

Page 4: ...he mains power cable from heat oil and sharp edges Observe the mains voltage The information on the name plate must be in agreement with the data for the mains power grid The pump s mains plug must be...

Page 5: ...the connection nipple 4 at b 3 Push the hose onto the connection nipple 4 4 Fix the hose to the connection nipple 4 e g with a GARDENA Hose Clamp Connect hose via the GARDENA Connection System With 17...

Page 6: ...line there is a pause of 10 minutes If the water level reaches sensor field S2 the pump switch es on automatically even within the pause of 10 minutes If this is the case regularly please select the n...

Page 7: ...ration remains active even after discon necting the power supply To stop manual operation disconnect the pump from the mains and take it out of the water Connect the pump to the power supply again and...

Page 8: ...the delivery drops suddenly Suction opening is clogged v Clean the suction opening with a water jet Hose is clogged v Remove the clog from the hose Pump starts and stops several times in succession R...

Page 9: ...very head bar m 0 7 7 0 0 9 9 0 0 9 9 0 Max submersion depth m 7 7 7 Min max cut in height mm 5 207 5 207 42 242 Min max cut out height mm 1 170 1 170 35 205 Residual water level mm 1 1 35 Dirty water...

Page 10: ...the purchaser nor a third party has attempted to open or repair the product Only Original GARDENA replacement parts and wear parts have been used for operation Presentation of the receipt Normal wear...

Page 11: ...legg rbe Charakteristika erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteristik Siurblio...

Page 12: ...ke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDE...

Page 13: ...ujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja origina...

Page 14: ...aparelho s a seguir designa do s no modelo lan ado por n s no mercado cumpre cumprem os requisitos das diretivas UE har monizadas as normas de seguran a UE e as normas espec ficas para estes produtos...

Page 15: ...Anbringungsjahr der CE Kennzeichnung Year of CE marking Ann e d apposition du marquage CE Installatiejaar van de CE aanduiding M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicazione...

Page 16: ...Newton Aycliffe County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan...

Reviews: