2. For Your  Safety 

According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0100, submersible pumps may only be used in swimming
pools, garden ponds, and fountains if the pump is operated via a
residual-current device with a residual-current rating of 

30 mA.

The pump must not be operated when there are persons in the
swimming pool or garden pond.

For safety reasons we recommend that you always operate 
the submersible pump via a residual-current device (DIN VDE
0100-702 and 0100-738).

v

Please contact your electrician.

In Austria, according to ÖVE B / EN 60 555 part 1 to 3, pumps
which are used in swimming pools and garden ponds, and
equipped with firm power cable should be fed via an ÖVE
approved isolating transformer – rated voltage must not exceed
230 V.

In Switzerland mobile appliances which are used outdoors, 
must be connected via a residual-current device.

According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0620, mains power cables must not have a smaller cross-
section than the rubber-sheathed cables of the designation 
H07 RNF. The cable length must be at least 10 m.

Data indicated on the type plate must match technical data of
the mains supply.

v

Take care that the electrical connections are made within dry
area, protected from flooding.

Protect plug and power cable from heat, oil and sharp edges.

v

Don’t use the power cable for plugging off.

The power cable or the float switch must not be used for mount-
ing or relocating the pump. For submerging or lifting / securing
the pump, fix a rope to the pump’s carrying handle.

Extension cables must meet the requirements of DIN VDE 0620.

v

Before operating the pump, first make a visual check, if there 
is any damage of the pump (esp. regarding power cable and
plug).

v

Observe the minimum water level and the max. delivery 
height (see 8. Technical Data).

A damaged pump must not be used.

v

In case of damage, please have the pump checked by our
GARDENA Service Centre.

During manual operation, the pump must be switched off as
soon as all the liquid has been pumped away.

v

Observe the pump at all times during manual operation.

In 

as-delivered condition,

the rotating feet are set to draining 

in the 

flat position

(1 mm).

v

Turn the rotating feet by 180° to 5 mm for normal operation.

The pump is raised by 5 mm.

Residual-current device 

In Austria 

In Switzerland 

Mains power 

Visual check 

Manual operation 

Notes on use 

Summary of Contents for 11000 SL automatic

Page 1: ...emploi Pompe d vacuation pour eaux claires NL Gebruiksaanwijzing Dompelpomp S Bruksanvisning Dr nkbar pump I Istruzioni per l uso Pompa sommersa E Manual de instrucciones Bomba sumergible P Instru es...

Page 2: ...private use around your house and garden They are predominantly desti nated for drainage after flooding transfer of liquids draining con tainers taking water from wells and shafts draining boats and y...

Page 3: ...st 10 m Data indicated on the type plate must match technical data of the mains supply v Take care that the electrical connections are made within dry area protected from flooding Protect plug and pow...

Page 4: ...tomatic deaerating valve eliminates any air pockets in the pump During this process air escapes through the vent bores 4 and air bubbles appear underwater This is not a defect of your pump but serves...

Page 5: ...an 3 5 cm fill the pump before operation over the universal fitting 7 with water Flat suction Normal operation v Turn the 3 swivel feet 8 v Turn the 3 swivel feet 8 180 to 1 mm 180 to 5 mm Flat suctio...

Page 6: ...o OPEN 2 Remove float switch cover B 3 Clean float switch 5 5a Warning Electric shock A Risk of injury due to electric shock V Disconnect the submersible pump from the mains before cleaning the suctio...

Page 7: ...rticles are jammed v Disconnect plug and clean in the suction base suction base see 5 Clean ing Pump runs but output Suction base is clogged v Disconnect plug and clean suddenly decreases suction base...

Page 8: ...hose Plug in system Min water level for operation 35 mm 35 mm Weight approx 7 kg 7 kg Max media temperature 35 C 35 C Mains voltage mains frequency 230 V 50 Hz 230 V 50 Hz Cut in height 185 mm 185 mm...

Page 9: ...eaflet We expressly point out that in accordance with the product liability law we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not origi...

Page 10: ...Tunguhalsi 1 110 Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 inf...

Reviews: