16
GB
Frost-free storage
6. Trouble-Shooting
Problem
Probable cause
Remedy
Pump is running,
Air cannot escape, since
v
Open pressure line
but doesn’t deliver.
pressure line is closed.
(e.g. kinked pressure pipe).
Air locks in the suction base.
v
Wait for max. 3 minutes
until the pump deaerates
automatically over the vent
valve. If necessary, switch
off and start it again.
Impeller clogged.
v
Disconnect plug and clean
impeller (see 5. Cleaning).
When starting the pump,
v
Fill the pump over the
water height falls below the
universal fitting
7
with
min. water level.
water.
Pump doesn’t start or
Thermal overload switch has
v
Disconnect plug and clean
suddenly stops during
switched the pump off due
impeller (see 5. Cleaning).
to overheating.
Observe max. media temper-
ature of 35 °C.
No power.
v
Check fuses and electric
connections.
Dirt particles are jammed
v
Disconnect plug and clean
in the suction base.
suction base (see 5. Clean-
ing).
Pump runs, but output
Suction base is clogged.
v
Disconnect plug and clean
suddenly decreases.
suction base (see 5. Clean-
ing).
Pump does not reach
The suction base cover
0
is
v
Disconnect plug and install
residual water height of 1 mm
missing in the suction base.
the suction base cover
0
during flat suction.
(see 5. Cleaning).
Pump does not switch on or
The pump is not upright.
v
Place pump in an upright
off automatically when set
position.
to automatic operation.
The integral float switch
5
v
Clean float switch (see
is sticking.
5. Cleaning).
Attention !
Repairs on electrical parts should only be done by our
GARDENA Service Centres.
If you have any problems with your Pump, please contact our Service.
7. Storage
Store the pump away from frost before the first frost sets in.
The device must not be added to the normal household waste,
it must be disposed of in accordance with local regulations.
Disposal :
(in accordance with
RL 2002 / 96 / EC)