Intended use 

Liquids to be pumped 

Please note 

GARDENA Submersible Pump 
11000 SL automatic / 15000 SL automatic 

Welcome to the garden of GARDENA ...

Please read these operating instructions carefully and observe 
the notes given. Use the instructions to familiarise yourself with 
the submersible pump, its correct use, and the notes on safety.

For safety reasons, children under 16 as well as persons not
familiar with these operating instructions should not use this
submersible pump.

v

Keep these operating instructions in a safe place.

1. Applications Range of Your GARDENA Submersible Pump

. . 

11

2. For Your Safety 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

3. Initial Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

13

4. Operation 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

14

5. Cleaning 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

15

6. Trouble-Shooting 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

16

7. Storage

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

16

8. Technical Data 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

17

9. Service 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

18

1. Applications Range of Your GARDENA Submersible Pump

GARDENA Submersible Pumps have been designed for private
use around your house and garden. They are predominantly desti-
nated for drainage after flooding, transfer of liquids, draining con-
tainers, taking water from wells and shafts, draining boats and
yachts as well as for water aeration and circulation for a limited
period of time.

Liquids which can be handled by the GARDENA Pump are the 
following: clean and slightly contaminated water (max. particle size
5 mm), swimming pool water (prerequisite is the recommended
dosage of additives) and soapy water.

The pump is fully submersible (waterproof sealed) and can be
immersed in the liquid down to a depth of 9 m.

The GARDENA Submersible Pumps are not designed for
continuous operation (e.g. continuous circulating opera-
tion) in a pond. Your pump’s life will be shortened corre-
spondingly by such operation.
Corrosive, easily combustible or explosive substances 
(e.g. gasoline, petroleum, nitro thinner), fats, oils, salt-water
and waste water of toilets and urinals must not be pumped.
The temperature of the liquid handled should not exceed
35 °C.

Contents

Summary of Contents for 11000 SL automatic

Page 1: ...emploi Pompe d vacuation pour eaux claires NL Gebruiksaanwijzing Dompelpomp S Bruksanvisning Dr nkbar pump I Istruzioni per l uso Pompa sommersa E Manual de instrucciones Bomba sumergible P Instru es...

Page 2: ...private use around your house and garden They are predominantly desti nated for drainage after flooding transfer of liquids draining con tainers taking water from wells and shafts draining boats and y...

Page 3: ...st 10 m Data indicated on the type plate must match technical data of the mains supply v Take care that the electrical connections are made within dry area protected from flooding Protect plug and pow...

Page 4: ...tomatic deaerating valve eliminates any air pockets in the pump During this process air escapes through the vent bores 4 and air bubbles appear underwater This is not a defect of your pump but serves...

Page 5: ...an 3 5 cm fill the pump before operation over the universal fitting 7 with water Flat suction Normal operation v Turn the 3 swivel feet 8 v Turn the 3 swivel feet 8 180 to 1 mm 180 to 5 mm Flat suctio...

Page 6: ...o OPEN 2 Remove float switch cover B 3 Clean float switch 5 5a Warning Electric shock A Risk of injury due to electric shock V Disconnect the submersible pump from the mains before cleaning the suctio...

Page 7: ...rticles are jammed v Disconnect plug and clean in the suction base suction base see 5 Clean ing Pump runs but output Suction base is clogged v Disconnect plug and clean suddenly decreases suction base...

Page 8: ...hose Plug in system Min water level for operation 35 mm 35 mm Weight approx 7 kg 7 kg Max media temperature 35 C 35 C Mains voltage mains frequency 230 V 50 Hz 230 V 50 Hz Cut in height 185 mm 185 mm...

Page 9: ...eaflet We expressly point out that in accordance with the product liability law we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not origi...