10
OPERATING INSTRUCTIONS
Before Lighting
The item was designed and approved for OUTDOOR USE ONLY. DO NOT use it inside a
building, garage or any other enclosed area.
Make sure surrounding areas are free of combustible materials, gasoline and other flammable
vapors or liquids.
Ensure there is no obstruction to air ventilation.
Be sure all gas connections are tight and there are no leaks.
Be sure the access panel is clear of debris.
Be sure any component removed during assembly or servicing is replaced and fastened prior to
starting.
Lighting
1. Ensure the control knob is in the "OFF" position.
2.
Push in control knob and rotate it to the “ON”
position. This will activate the built-in igniter and light
the burner. If necessary, keep depressing and rotating
knob until burner lights.
3. Once burner is lit, hold control knob in for at least 30
seconds and release.
4. If burner does not stay lit, turn to “OFF” position and
wait 5 minutes and repeat steps 2 and 3.
5. If burner does not light, use a lighter positioned
against the bottom of emitter screen at burner
location.
Checking for Leaks
Make 2-3 oz. of leak solution by mixing one-part liquid dish soap with three-parts water.
1. Make sure control knobs are off.
2. Spoon or brush several drops (or use squirt bottle) of solution onto the gas regulator and tank
connection.
3. Turn on the gas cylinder valve. Inspect the connections and look for bubbles.
a. If no bubbles appear, the connection is safe.
b. If bubbles appear, there is leakage. Loosen and re-tighten this connection. If it still leaks,
please call customer service.
Note:
Whenever gas connections are loosened, removed or re-assembled, you must perform a complete
leak test.
1
OFF
ON
HIGH
LOW