TR-RC1xx - User Manual
11
TR-RC reference information
This section of the user manual contains information about the TR-RC’s
specification, ratings and restrictions, and event and error codes.
11.1
Specifications and ratings
TR-RC120
TR-RC122
User interface
Ethernet and pushbutton
Output channel
One constant current output with SafeSense
Output current
Up to 1.2A continuous
or 2.0A pulsed
Up to 1.25A continuous
or 10.0A pulsed
Maximum
output voltage
Up to 24V, continuous
or pulsed
Up to 24V continuous or
up to 48V pulsed
Pulsed output
average power
Max 25W
Max 30W
Trigger input
Smart input compatible with 3V-24V, TTL, NPN,
and PNP.
Input Impedance (nom) 8kohms
Pulse timing
From 100µs to 100ms in steps of 100µs
Delay from
trigger to pulse
Maximum 10µs fixed latency plus user adjustable
steps of 100µs to a maximum of 100ms
Timing
repeatability
(delay)
±5µs (delay + pulse up to 60ms)
Otherwise ±50µs
Switch mode
latency
Maximum 100µs
Trigger rate
Maximum 100Hz
Supply voltage
Regulated 24VDC ±10%
A SELV power supply is required
Dimensions
(excluding
DIN fixing)
120mm long x 35mm
wide x 104mm high
120mm long x 58mm
wide x104mm high
Weight
0.3kg
0.4kg
Mounting
DIN rail mount
Operating
temperature
5° to 50°C
Humidity
Up to 95% (non-condensing)
—
38
—