TR-RC1xx - User Manual
Set switched mode
This command sets the output to switched mode and allows the
brightness to be set:
RW1,s
Where:
s
= brightness setting in percent (0 to 999).
Set the option flags
This command sets the flags for error detection, trigger sense, and
SafeSense:
RE1,m
Where the following code applies:
m
Error
detection
Trigger sense
SafeSense
0
Enabled
+
Enabled
2
Disabled
+
Enabled
4
Enabled
–
Enabled
6
Disabled
–
Enabled
8
Enabled
+
Disabled
10
Disabled
+
Disabled
12
Enabled
–
Disabled
14
Disabled
–
Disabled
Set the internal trigger
These commands control the internal trigger. When set, the output
is triggered using an internal trigger signal. Type in:
TT0
to disable the internal trigger
TT1
to enable the internal trigger using the period last set
TT1,p
to enable the internal trigger and set the period.
Where:
p
= trigger period in milliseconds.
Note 1:
The
TT1
command does not disable external triggers.
Note 2:
This setting can be saved to non-volatile memory using the
AW
command.
Save the settings to memory
AW
This command saves the settings to non-volatile memory. If you
power cycle the TR-RC before sending the
AW
command, all
changes are lost and the unit returns to the values set before the last
AW
command.
—
33
—