  72.000in

1828.80mm

 

48.000IN

[1219.20mm]

REUSE THE DRILL TEMPLATE TO MARK MOUNTING HOLES ON THE CEILING

AA

AB

DETAIL AA

SCALE 1 : 2

DETAIL AB

SCALE 1 : 2

CEILING JOISTS

11/64"

[ 4.5mm]

2 3/8"

[60mm]

DRILL MARKED MOUNTING HOLES

(2) MOUNTING HOLES REQUIRED

PER CEILING BRACKET

MARKED MOUNTING HOLE

WITH PENCIL

MOUNTING HOLE DIMENSIONS

AC

DETAIL AC

SCALE 1 : 10

CEILING 

JOIST

CEILING 

BRACKET

WOOD

SCREW

DRILL

SUPPLIED

NUT DRIVER

WOOD

SCREW

STEP 1: 4FTX 6FT RACK-FOR CEILING BRACKET INSTALLATION (WOOD JOIST) 

WE PROVIDED WOOD SCREWS AND SOLID CONCRETE CEILING ANCHORS FOR THIS INSTALLATION.

PLEASE DETERMINE THE TYPE OF CEILING YOU HAVE BEFORE STARTING.

WOOD JOIST:

A: USE A STUD FINDER TO LOCATE THE CEILING WOOD JOISTS. 

     

NOTE:

 

USE THE DRILL TEMPLATE TO MARK THE MOUNTING HOLES FOR INSTALLATION.

A1: START FROM THE LEFT, PLACE THE DRILL TEMPLATE AND MARK THE (2) HOLES AT CENTER OF THE JOIST LOCATIONS.

A2: FROM THE (1) END MEASURE 72", PLACE THE DRILL TEMPLATE AND MARK THE NEXT SET OF (2) HOLES.

B:  PILOT HOLES FOR WOOD JOIST: USE A 11/64" (4.5mm) DIA. DRILL BIT AND DRILL A 2 3/8" (60mm) DEEP HOLE FOR

     EACH SCREW.

C: FASTEN THE CEILING BRACKETS WITH THE WOOD SCREW. USE A DRILL & SUPPLIED NUT DRIVER.

     

PAGE 5

KEEP EACH SET OF CEILING BRACKETS IN A STAIGHT LINE

Summary of Contents for GT7008A

Page 1: ...KG 22 40IN 560 1010mm UNIFORM LOAD PAGE 1 UNIFORM LOAD 22 40IN 560 1010mm 450LBS 204 KG MAXIMUM CAPACITY GT100010A 4FT X 6FT RACK GT7008A 4FT X 4FT RACK INSTALLATION GUIDE FOR GT7008A GT7009A GT100010...

Page 2: ...CKET 4FT X 4FT RACK X4 4FTX 6FT RACK X4 4FT X 8FT RACK X6 CENTER TOP RAIL 4FT X 4FT RACK 0 4FTX 6FT RACK 0 4FT X 8FT RACK X2 4FT X 4FT RACK 0 4FTX 6FT RACK 0 4FT X 8FT RACK 2 CONNECTOR BRACKET GRID PA...

Page 3: ...APE MEASURE PENCIL STUD FINDER LADDER ELECTRIC DRILL WITH DRILL BITS HAMMER DRILL FOR CONCRETE WITH MASONARY DRILL BITS DRILL TEMPLATE 1 PER KIT RUBBER MALLET DOMED LABEL HARDWARE 4FT X 4FT RACK 10 PE...

Page 4: ...S INSTALLATION PLEASE DETERMINE THE TYPE OF CEILING YOU HAVE BEFORE STARTING WOOD JOIST A USE A STUD FINDER TO LOCATE THE CEILING WOOD JOISTS NOTE USE THE DRILL TEMPLATE TO MARK THE MOUNTING HOLES FOR...

Page 5: ...NCHORS FOR THIS INSTALLATION PLEASE DETERMINE THE TYPE OF CEILING YOU HAVE BEFORE STARTING WOOD JOIST A USE A STUD FINDER TO LOCATE THE CEILING WOOD JOISTS NOTE USE THE DRILL TEMPLATE TO MARK THE MOUN...

Page 6: ...TION PLEASE DETERMINE THE TYPE OF CEILING YOU HAVE BEFORE STARTING SOLID CONCRETE CEILING A USE THE DRILL TEMPLATE TO MARK THE MOUNTING HOLES FOR INSTALLATION A1 START FROM THE LEFT PLACE THE DRILL TE...

Page 7: ...THIS INSTALLATION PLEASE DETERMINE THE TYPE OF CEILING YOU HAVE BEFORE STARTING SOLID CONCRETE CEILING A USE THE DRILL TEMPLATE TO MARK THE MOUNTING HOLES FOR INSTALLATION A1 START FROM THE LEFT PLAC...

Page 8: ...PER CEILING BRACKET ATTACHMENT REQUIRED 1 PER CEILING BRACKET ATTACHMENT CENTER RAILS CEILING BRACKET CENTER TOP RAIL CEILING BRACKET CEILING BRACKET CORNER TOP RAIL PAGE 8 STEP 2 VERTICAL RAIL ASSEM...

Page 9: ...MAY RESULT IN THE CEILING BRACKETS FAILING AND CAUSE PERSONAL INJURY AND OR PROPERTY DAMAGE DO NOT ATTACH THE RAIL ASSEMBLY TO ONE SIDE OF THE SCREWS OR ANCHORS STEP 3 4FT X 4FT 4FT X 8FT RACK VERTIC...

Page 10: ...E PERSONAL INJURY AND OR PROPERTY DAMAGE DO NOT ATTACH THE RAIL ASSEMBLY TO ONE SIDE OF THE SCREWS OR ANCHORS 48 72 CEILING BRACKET CORNER RAIL ASSEMBLY STEP 3 4FT X 6FT RACK VERTICAL RAIL ASSEMBLIES...

Page 11: ...EN SCREW GRID PANEL JOINT CONNECT THESE HOLES CONNECT THESE HOLES CONNECT THESE HOLES CONNECT THESE HOLES STEP 4 4FT X 4FT 4FT X 8FT GRID PANEL ASSEMBLY 1 FASTEN THE GRID PANELS TOGETHER WITH SCREW AN...

Page 12: ...SCREWS FASTEN SCREW FASTEN SCREW GRID PANEL JOINT CONNECT THESE HOLES CONNECT THESE HOLES CONNECT THESE HOLES CONNECT THESE HOLES STEP 4 4FT X 6FT GRID PANEL ASSEMBLY 1 FASTEN THE GRID PANELS TOGETHER...

Page 13: ...TAND BEFORE STARTING INSTALLATION PLEASE CONTACT A PROFESSIONAL INSTALLER IF YOU ARE UNSURE OF ANY PART OF THIS INSTALLATION INSPECT YOU GARAGE CEILING S CONDITION THE CEILING MUST BE CAPABLE TO SUPPO...

Page 14: ...INSPECT YOU GARAGE CEILING S CONDITION THE CEILING MUST BE CAPABLE TO SUPPORT THE WEIGHT OF THE OVERHEAD STORAGE RACK AND ITEMS ON IT REINFORCE THE CEILING AS NEEDED THESE PRODUCTS ARE INTENDED FOR U...

Page 15: ...PAGE 15...

Page 16: ...PAGE 16 NOTES...

Reviews: