8-10. INSTALL PHOTO EYE SAFETY SYSTEM
Cover Flap with
Terminal Marking
1
2
TX
Receiver (RX) or
Transmitter (TX)
Mark
Indicator Light
Lens
Fastening Wheel
Terminal Holes
Wiring to Powerhead
To Terminal 1
To Terminal 2
Tabs
Sensor Cap
Sensor Cap Fastener
1
2
2
1
Fastening Wheel
Photo Eye Sensor
Wire terminal must point
downward towards
garage floor
Fig. 22
To provide the maximum amount of protection, the photo eye sensors
must be mounted between 3” and 4-1/2” above the floor (see Fig. 23).
Wall Stud
Mounting
Bracket
Lag Screws (2)
Wall
3” to 4-1/2”
from floor
3” to 4-1/2”
from floor
Fig. 23
Receiver
Transmitter
Transmitter
Receiver
Fig. 24
CONNECTING WIRES TO THE PHOTO EYE SENSORS:
(if required). Fig. 22
• Open the black cover flap.
• Insert stripped end of wires into terminal holes by pushing directly into
hole (white wire in terminal #1 and wire with stripes into terminal #2).
• After inserting the wire in the proper terminal, pull on the wire to ensure
proper connection has been made. If the wire pulls out repeat the
above steps.
• Place the wires in the slot from the right side of the cover and close cover.
MOUNTING THE PHOTO EYE SENSORS TO BRACKET:
(if required). Fig. 22
• Attach the sensor cap and the sensor cap fastener to the bracket.
• Secure the photo eye sensor to the bracket with fastening wheel.
• Repeat process for the other sensor.
MOUNTING THE PHOTO EYE SENSOR BRACKETS TO WALL:
• Locate the mounting position for brackets (bracket can be mounted in any
position as long as photo eye beam will have a clear path from one side
of door to the other side after mounting).
• Use the bracket mounting holes as a template to locate and drill (2) 3/16”
diameter pilot holes on both sides of the garage door 3” to 4-1/2” above
the floor.
• Secure the bracket assemblies with 1/4” x 1-1/2” lag screws (see Fig. 23).
• Align photo eye sensors, so they face each other.
MOUNTING THE PHOTO EYE SENSORS DIRECTLY TO WALL
(optional):
• Locate the installation position (see Fig. 23).
• Remove sensors from brackets.
• Use the photo eye sensor mounting holes as a template to locate and
drill two 1/6” pilot holes into wall (if mounting to drywall instead of wood,
drill two 3/16” pilot holes).
• Secure the photo eye sensor assemblies with #6 screws and anchors
(not provided).
• Repeat process for the other photo eye sensor.
DUAL DOOR INSTALLATION:
• In dual door installations, the transmitter (TX) and the receiver (RX) photo
eye sensors (as marked on each of the photo eye components) should
be mounted (see Fig. 24).
• TX and RX marks located on the top side of the PCB, near the terminal
area (see Fig. 22).
Summary of Contents for CarGO 500