016
017
ZT-PTS
SERIES
ZT-PTS
SERIES
Diagnostic
A. PAN Origin Test
Zero point of Pan is Located during the Panning test.
B. Tilt Origin Test
Zero point of Tilt is Located during the Tilt Test
C. TX Connection Test
Wait for 60 seconds for TX Connection Test.
During 60 seconds, the camera is must received a signal by any control
equipment as DVR or controller.
Then OK is displayed then automatically verifying TX Connection Test
D. Camera Comm. Test
Camera communication is also checked.
OK should be displayed in these four tests before installation.
If all the above Tests are OK, “NOW EEPROM CHECKING” and “ALL DATA
INITIALIZING” is displayed and the camera is ready to operate.
Whenever the IR Camera is power on, a standard diagnostic is operated.
• If “Not Tested” is displayed in the test.
- The result which is not received any signal from DVR or controller.
- Wrong connecting way such as the protocol, baud rate or RS-485
connection.
The use may check the install way carefully.
CAMERA ID
: 001
BAUD RATE
: 2400BPS
WAITING............
PAN ORIGIN
TEST OK
TILT ORIGIN
TEST OK
TX CONNECTION
TEST OK
CAMERA COMM
TEST OK
OSD Menu Setting
MAIN MENU
DOME SETUP
CAMERA SET
PRESET
AUTO SCAN
TOUR
PATTERN
ALARM
SECTOR
EXIT
PATTERN SET
PATT NO
: 01
PATT TITLE
: PATTERN 01
DATE FILL
: 100%
SAVE
EXIT
ALARM SET
ALARM NO
: 01
ALARM INPUT
: OFF / ON / NC
ALARM ACT
: 001
AUX ACT
: BLK
SAVE
EXIT
SECTOR
SECTOR NO
: 01
SECTOR ID
: SECTOR01
SECTOR START
: XXX.X.XX.X
SECTOR END
: XXX.X.XX.X
SAVE
EXIT
DOME SET
CAMERA ID
: CAM 1
RECOVER
: OFF
MANUAL SPEED : 150
℃
ALARM
: DISABLE
LANGUAGE
: ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT
CAMERA SET
COLOR MODE
: B/W
INVERS MODE
: OFF
D-ZOOM
: OFF
AGC MODE
: ON
AGC MAX LEVEL : x1.5
T-RANGE MIN
: 020
℃
T-RANGE MAX
: 045
℃
CALI. MODE
: AUTO
CALI. INTERVAL : 600SEC
EXIT
PRESET SET
PRESET NO
: 01
PRESET ID
: PRESET 01
PAN : XXX.X
TITL : XX.X
SAVE
EXIT
AUTO SCAN SET
START ANGLE
: XXX.X.XXX.X
END ANGLE
: XXX.X.XXX.X
DIRECTION
: CW
ENDLESS
: OFF / ON
SPEED
: 10°/S
DWELL TIME
: 03
SAVE AND EXIT
EXIT
TOUR SET
TOUR NO
: 01
TOUR TITLE
: TOUR 01
TOUR STEP
: 01
PRESET NO
: 01
DWELL TIME
: 03
SPEED
: 200°/S
SAVE
EXIT
DOME SET
[SYSTEM SET]
SYSTEM LOCK
: OFF
[PASSWORD]
[OSD DISPLAY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
SYSTEM SET
FLIP STATUS
: NOMAL
MOTOR TORQUE : LOW
RECOVER ORIGIN : ON
[PREVIOUS PAGE]
OSD DISPLAY
CAMERA ID
: ON / OFF
PRESET ID
: ON / OFF
SECTOR ID
: OFF / ON
COORDINATE
: ON / OFF
[PREVIOUS PAGE]
[SYSTEM STATUS]
PROTOCOL
: PELCO D/P
BAUD RATE
: 2400BPS
FIRMWARE VER : 1.10a
UPGRADED DATE : 02.02.12
CAMERA MODULE: TSM-72
[PREVIOUS PAGE]
[INITIALIZATION]
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT]
[PREVIOUS PAGE]]
A. OSD Menu Table