Use 24 V AC / 12 V DC for this device.
Connecting the AC Power
㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃
Use 24 V AC (20.4 - 27.6 V AC) 50 Hz / 60 Hz to power the device. Refer to figure 5 as to
connecting the power.
Peel back the casing of the power cord about 10 mm and insert the twisted wire directly into the
terminal.
If the power cord can not be inserted, try pressing the button on the terminal and inserting
again.
Connecting the DC Power
㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃 㻃
Use 12 V DC (10.2 – 13.8 V DC). Refer to figure 6 as to connecting the power.
When a fuse is necessary, connect a slow blow fuse within 10 cm of the power terminal (+
terminal side).
Connecting the Power
En-8
Warning:
Be careful not to short circuit the power cord when connecting it to the
device.
Pay attention to the power polarity.
390 mA of current is required for each device.
Be careful with following items when choosing and connecting the
power cord.
1) Allowable current for the power cord
2) Power cord size and length
Back panel
Button
Transformer
DC power
Fuse
Button
Pull on the power cord and make sure that it is connected.
Make sure the wire of power cord is not exposed outside of the terminal.
Use class 2 power supply. Connect the GND line to GND terminal.
Caution
270 mA (24 V AC) of current is used by this device.
The capacity to supply multiple connections is required when multiple
devices are connected to one power source.
Caution
Caution
Figure 6
Figure 5