PixelMASTER GXi Series NVR
User’s Manual
05-2014-A
47
47
OPERATION: You can configure Enable/Disable Relay output.
MODE: You can configure operation type of Relay output.
TRANSPARENT: Keep Relay output until event triggering stopped.
LATCHED: Keep relay output as long as duration specified.
DURATION: If the alarm output mode is configured as Latched. You can configure
duration for relay output.
TYPE : Define the signal type of Relay output
N/O (Active Low): When event triggered, the relay will go to
‘Close’ state from the
‘Open’.
N/C(Active High): When event triggered, the relay will go to
‘Open’ state from the
‘Close’
HEALTH CHECK: If you select
“ON”, when NVR system Event is triggered, relay output
will be activated. (booting / Fan Error / HDD Error
…)
SENSOR: When sensor input, relay output will be activated.
VIDEO LOSS: When video loss occurred, replay output will be activated.
MOTION: When motion triggered, replay output will be activated.
6.5.3 BUZZER OUTPUT SETUP
You can configure Buzzer output when event triggered.
OPERATION: You can configure Enable/Disable of the Buzzer.
HEALTH CHECK: If you select
“ON”, when NVR system Event is triggered, relay output
will be activated. (booting / Fan Error / HDD Error
…)
MODE: You can configure operation mode of Buzzer output.
TRANSPARENT: Keep buzzer output until event operation is stopped.
LATCHED: Keep buzzer output as long as duration specified.