0
Fuses
RC-PSB1
RC-PSB2
Mains input
230VAC
3.15A
3.15A
Power input (F0)
24VAC
3.15A
5A
Power PTZ output (F1)
24VAC
2A
2A
Washer pump (F2)
24VAC
1A
2A
Connecting the composite cable
1 Open one of the knock-out panels of the wiring centre box and fit a suitable
cable water-sealing cable grommet.
2 Feed the bare ends of the composite cable in through the grommet and connect
each cable within the wiring centre as follows:
•
Primary video
Fit a BNC connector to coaxial cable marked as ‘Video 1’ and connect it to the
BNC socket labelled ‘VIDEO IN 1’.
•
Secondary video
(if present)
Fit a BNC connector to coaxial cable marked as ‘Video 2’ and connect it to the
BNC socket labelled ‘VIDEO IN 2’.
•
Power
Connect the Red cable to the terminal marked ‘PTZ 1P’.
Connect the Black cable to the terminal marked ‘PTZ 1N’.
•
Washer
Connect the Orange cable to the upper terminal marked ‘AUX1‘.
Connect the White cable to the upper terminal marked ‘AUX2’.
•
RS485 telemetry
Connect the Yellow cable to the upper terminal marked ‘DATA 5’. Connect
the Blue cable to the upper terminal marked ‘DATA 6’.
•
Earth
Connect the Green/Yellow cable to the Earth connection of the mains input
terminal block.
The IR Lamp and Ethernet terminals are reserved for future use.
Summary of Contents for C-AllView
Page 1: ...C AllView C AllView Ti installer s guide...
Page 2: ......