Modbus – slave devices can interface directly with a Q.station via the USB port.
Connect an RS232 to RS485 converter (i.e. ISK103) between the Q.station and
the slave. Configure the Modbus variable with the correct register
settings/format.
CAN Input – it is possible to read and write CAN data with the Q.station. We
setup the CAN inputs under the virtual variables section. Double-click on the
CAN Input to modify the CAN ID, byte order, format, start bit, and bit length. If a
CAN data base file is available, the pre-defined variables can be selected from
this file; click the CAN DB button to navigate to the file.