GT7 Terminal
Configuration
56
HB_GT7-2x00-3x00--EN_12
www.gantner.com
- Only locking SMART.Locks by command:
For the GAT SMART.Lock system only. This option is set by the app and cannot be
changed here. When enabled, the locker can only be locked when a previous locking
command is sent.
- Locking timeout:
This option is set by the app and cannot be changed here. The displayed value (in
seconds) shows the time for locking via command.
- Auto close free locker:
For the GAT NET.Lock system only. This option is set by the app and cannot be
changed here. When enabled, a user can close an unoccupied free locker by pushing
the locker door shut (door is not locked, only held shut) and reopen it by pressing
again. The lock LED remains green to indicate its status.
NOTE!
The door is not locked. It can be opened by anyone without a data carrier.
- Auto lock personal locker:
This option is set by the app and cannot be changed here. When this setting is
enabled personal lockers can be locked automatically when the locker door is pushed
shut without needing to use a data carrier.
- Enable locker light:
Enable this setting to allow lockers with an integrated LED light in the lock (GAT
NET.Lock 7020 USB) to turn on automatically when the door is opened.
- Enable USB charging:
Enable this setting to allow lockers with USB charging functionality (GAT NET.Lock
7020 USB) to be used.
- Lock manipulation detection:
For the GAT NET.Lock system only. This setting prevents the locker from being locked
when manipulation of lock is detected, e.g., manipulation of the door closed sensor.
- Alarm mode:
For the GAT NET.Lock system only. This setting turns the alarm function on/off. When
an alarm is triggered, the GAT NET.Lock 7xxx locks emits a loud alarm tone (see
setting “Acoustic alarm” to turn off), the status LED flashes red, and the locker
management software is notified.
- Beeper:
For the GAT NET.Lock system only. When this setting is enabled, the lock beeps to
signal each locking and unlocking action.
- Acoustic alarm:
For the GAT NET.Lock system only. Switches on/off the acoustic signal in the GAT
NET.Lock in the event of an alarm.
- GAT Lock 5xxx compatibility:
For the GAT NET.Lock system only. When this setting is enabled, the LED of the GAT
NET.Lock functions in the same way as with the predecessor GAT Lock 5000 system,
i.e., the LED color is limited to red. The LED is off when the door is open, on when the
door is locked, and the LED flashes red to indicate when a data carrier should be read.
- Show rented:
For the GAT NET.Lock system only. Enable this option to indicate whether a personal
locker has been rented or not. When a locker has been rented, the lock LED is then
red even if it is not locked.
NOTE!
To ensure the correct LED signaling, disable this option for dynamic lockers.