Emergency Mode
Funds
Simulated account balance (in cents) for every data
carrier in emergency mode
Integer
8000
Payment type
Select the price setting: “Default Price”, “Price List”,
“Discount Group”, “Discount”, “Surcharge”
Menu
Default Price
Discount/Surcharge [%]
Define a percentage price discount / surcharge
Integer
0
User group
Define the user group
Integer
0
Pricelist/Disc grp
Define the pricelist / discount group
Integer
0
Emergency revalue
Option to allow revaluing in emergency mode
Boolean
False
Pseudo always idle
Option to simulate a valid card with emergency mode
settings. The user must present their data carrier only
once per vending transaction.
Boolean
False
Unknown cash value
Op
tion to send the “Cash value not determined” value
when emergency values are used (0xFFFF). Not
supported by many vending machines.
Boolean
False
Offline Mode
Cash segment NB
GANTNER cash segment to read account data from
Integer
1
Comm. Gateway
Enable Comm Gateway
Option to enable the communication gateway
Boolean
False
Reader
Read Mifare
Option to read MIFARE
data carriers
Boolean
True
Read Legic Prime
Option to read LEGIC Prime data carriers
Boolean
True
Read Legic Advant
Option to read LEGIC Advant data carriers
Boolean
False
Read ISO 15693
Option to read ISO 15693 data carriers
Boolean
False
Read FeliCa UID
Option to read the UID of FeliCa data carriers
Boolean
False
Read Inside Secure UID
Option to read the UID of Inside Secure data carriers
Boolean
False
Read ISO 14443B UID
Option to read the UID of ISO 14443B data carriers
Boolean
False
LEGIC
Options for reading LEGIC data carriers.
Company ID
Company ID for the device. All data carriers must have
the same company ID to be used with the device
Hex
9999
Subsite
Additional key for division of site keys
Hex
00
Subsite enabled
Option to check the subsite keys of data carriers
Boolean
False
SSC
Data carrier segment ID for SSC (cash segment)
Hex
1A
MIFARE
Options for reading MIFARE data carriers.
Site key
Site key of the device. All data carriers must have the
same site key to be used at the device
Hex
73E0818B…
Subsite
Additional key for division of site keys
Hex
00
Enable subsite
Option to check the subsite keys of data carriers
Boolean
False
Position Locker 1
Indicates the data carrier segment for locker 1 data
Integer
4
Position Locker 2
Indicates the data carrier segment for locker 2 data
Integer
5
ISO
Options for reading of ISO 15693 data carriers.
Site key
Site key of the device. All data carriers must have the
same site key to be used at the device
Hex
73E0818B…
Subsite
Additional key for division of site keys
Hex
00
Subsite enabled
Option to check the subsite keys of data carriers
Boolean
False
Position FID
Indicates the data carrier segment for general data
Integer
13
Position Locker 2
Indicates the data carrier segment for certificate data
Integer
15
Position Locker 1
Indicates the data carrier segment for locker 1 data
Integer
19
Position Locker 2
Indicates the data carrier segment for locker 2 data
Integer
23
Third Party
Segment ID
Segment ID for third party data on the data carrier
Integer
Data start
Start of the third party data segment
Integer
Data length
Length of the third party data segment
Integer