![background image](http://html1.mh-extra.com/html/gandg/wpx-series/wpx-series_installation-manual_3068988004.webp)
Brown or Black (Line)
Blue or White (Neutral)
Green (Ground)
Power Supply
Light Fixture(s)
Black
(Common)
Black
(Common)
Red
(+48VDC)
Red
(+48VDC)
All Connections Occur in Box
WPX
INSTALLATION MANUAL PAGE 4
STRONG. SIMPLE. COMPACT.
Install the jumper cables between the mounted fixtures. The 1FT jumper (WPX-JMP1) may be looped for
minimum distance between fixtures. Longer cables may be sleeved through PVC, EMT, or wiremold if desired.
Depending on the distance between the power supply and the first fixture, the leader cable may have to be
extended with proper gauge of wire. Please see table 3.2.
Ensure the last fixture in every daisy chain is capped. Each leader cable is packaged with an end cap.
Failure to cap the fixture will result in water ingress.
5. Connect Fixtures Together
7. Connect the Leader Cable and Power Supply
6. Attach the End Cap
Figure 5.1:
Fixture Jumper
www.ggled.net
T
800.285.6780
E
Figure 7.1 and 7.2:
Leader Cable Dimensions and Wiring
(White)
(Black)
Figure 7.3:
Standard Power Supply Connection
Rev Date 19 0312