10K Sensor Ohms Chart 

OHM 

OHM 

OHM 

OHM 

OHM 

 

 

20 

46225 

40 

26100 

60 

15310 

80 

9297 

100 

5827 

 

 

21 

44879 

41 

25391 

61 

14921 

81 

9076 

101 

5697 

 

 

22 

43577 

42 

24704 

62 

14543 

82 

8861 

102 

5570 

 

 

23 

42318 

43 

24037 

63 

14176 

83 

8651 

103 

5446 

 

 

24 

41099 

44 

23391 

64 

13820 

84 

8447 

104 

5326 

 

 

25 

39919 

45 

22764 

65 

13473 

85 

8249 

105 

5208 

 

 

26 

38777 

46 

22156 

66 

13136 

86 

8056 

106 

5094 

 

 

27 

37671 

47 

21566 

67 

1209 

87 

7867 

107 

4982 

 

 

28 

36601 

48 

20993 

68 

12491 

88 

7684 

108 

4873 

 

 

29 

35565 

49 

20438 

69 

12182 

89 

7506 

109 

4767 

 

 

30 

34561 

50 

19900 

70 

11882 

90 

7333 

110 

4664 

 

 

31 

33590 

51 

19377 

71 

11589 

91 

7164 

111 

4563 

 

 

32 

32648 

52 

18870 

72 

11305 

92 

6999 

112 

4464 

 

 

33 

31737 

53 

18377 

73 

11029 

93 

6839 

113 

4368 

 

 

34 

30853 

54 

17899 

74 

10761 

94 

6683 

114 

4274 

 

 

35 

29998 

55 

17435 

75 

10500 

95 

6530 

115 

4183 

 

 

36 

29169 

56 

16985 

76 

10246 

96 

6382 

116 

4094 

 

 

37 

28365 

57 

16548 

77 

9999 

97 

6238 

117 

4007 

 

 

38 

27587 

58 

16123 

78 

9758 

98 

6097 

118 

3922 

 

 

39 

26832 

59 

15711 

79 

9525 

99 

5960 

119 

3839 

 

 

 

Page 16 

Summary of Contents for R-410A

Page 1: ...G F Manufacturing Service Manual Version 2 0 April 2010 Any tech working on these units must read this manual Any questions please call service department from the job site 954 318 6900...

Page 2: ...gnostic 6 No Flow 6 Defrost 6 Low Refrigerant Pressure 7 Water Flow Lockout 7 Evaporator Sensor Malfunction 7 Water Sensor Malfunction 7 Components of Service 8 Charge 8 Thermal Expansion Valve 8 Comp...

Page 3: ...ATTENTION If you find that it is mis plumbed un bonded etc contact the warranty department and let them handle it Do not bad mouth an installation Attention Warning and Caution boxes have been place...

Page 4: ...ce programming calls and to be able to handle most scenarios found in the field The board will display which mode it is in Pool Heat Spa Heat Simply raise or lower temp by pushing the Up or Down arrow...

Page 5: ...t point again This option is only for Heat Cool units 4th Option Pool Cool Disable Once this option is enabled it will give you a pool cool mode on display use Mode buttonto toggle This option is only...

Page 6: ...ter Temperature Calibration This option is for calibrating the water temperature sensor and will show the amount of calibration in plus or minus at the bottom of display 13th Option Load Defaults In t...

Page 7: ...is is a 10k sensor If it is open or outside its range you ll get this error Check connections before replacing Water Sensor Malfunction This is also a 10k sensor If it is open or outside of its range...

Page 8: ...superheat ATTENTION Check temperature on both sides of filter If more than 2 degrees different the filter is clogged TXV Thermal Expansion Valve All units are manufactured with adjustable TXV s If you...

Page 9: ...the top on unit Cut wire tie on fan wire bundle outside of the control box Lift top of unit flip over and stand on end next to unit Bleed run capacitor Remove wires from compressor Note colors and po...

Page 10: ...igerant Cut wire tie holding fan wires bundled next to control box Remove 4 screws holding top on unit Lift top off flip top over and lay on end next to unit Cut or break female half of unions off bac...

Page 11: ...n and remove motor Reverse procedure to install new motor Be sure to reinstall strain relief bushing where wires penetrate control box and replace fan motor capacitor WARNING DO NOT Cut old WTS wire a...

Page 12: ...flow switch to control box Install new switch and reverse procedure R R High or Low Pressure Switch Turn off power Remove front cover Cut high pressure switch wires near switch Unscrew HP switch using...

Page 13: ...e Installations under palm trees inside screened porches etc may help hide unit but will drastically reduce the performance of the unit You will not have a happy customer The unions were to the side o...

Page 14: ...Page 14...

Page 15: ...028 9 CAPACITOR 7 5UF 370V 1001009 10 PRESSURE SWITCH HIGH 540 1001054 11 PRESSURE SWITCH LOW 37 1001055 12 WATER PRESSURE SWITCH 1001012 13 TOP COVER 3003014 14 BASE PAN 3003013 15 FRONT PANEL 300301...

Page 16: ...47 21566 67 1209 87 7867 107 4982 28 36601 48 20993 68 12491 88 7684 108 4873 29 35565 49 20438 69 12182 89 7506 109 4767 30 34561 50 19900 70 11882 90 7333 110 4664 31 33590 51 19377 71 11589 91 716...

Page 17: ...g section of this manual or call your dealer This may save you the cost of a service call If you still need help follow the instructions below 0 12 3 45678 9 5 When asking for help or service please p...

Reviews: