Status LEDs

G&D MultiPower-2-12V · 

5

English

Status LEDs

LED

Status

Meaning

In Main

On

The external main power supply (

Main

) provides the 

required voltage.

Off

The external main power supply (

Main

) is switched off 

or not connected.

In Red.

On

The external redundant power supply (

Red.

) provides the 

required voltage.

Off

The external redundant power supply (

Red.

) is 

switched off or not connected.

Power Out 1

On

Power supply output 1 provides the required voltage.

Off

Power supply output 1 is switched off.

Power Out 2

On

Power supply output 2 provides the required voltage.

Off

Power supply output 2 is switched off.

Summary of Contents for MultiPower-2-12V

Page 1: ...Guntermann Drunck GmbH www gdsys de MultiPower 2 12V A9100366 1 0 Installationsanleitung DE EN Installation Guide...

Page 2: ...ausschluss G D bernimmt keine Gew hrleistung f r Ger te die nicht bestimmungsgem eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere u ere Besch digungen aufweisen welche nic...

Page 3: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there...

Page 4: ...Inhaltsverzeichnis iii G D MultiPower 2 12V Inhaltsverzeichnis Sicherheitshinweise 1 Einleitung 3 Lieferumfang 3 Installation 4 Inbetriebnahme 4 Status LED 5 Status Output Buchsen 6 Technische Daten 7...

Page 5: ...installation ensure that the device has been disconnected from all power sources Disconnect all power plugs and all power supplies of the device D branchez toutes les sources d alimentation Avant l i...

Page 6: ...Ger te jederzeit zug nglich bleiben Stolperfallen vermeiden Vermeiden Sie bei der Verlegung der Kabel Stolperfallen Betreiben Sie das Ger t ausschlie lich im vorgesehenen Einsatzbereich Die Ger te si...

Page 7: ...hse der zentralen Stromversorgung verbunden Mindestens eine externe Spannungsversorgung Tischnetzteil liefert die Spannung der zentralen Stromversorgung Eine zweite externe Spannungsversorgung gew hr...

Page 8: ...le 12V 4 75A an Red Schlie en Sie eines der mitgelieferten Tischnetzteile 12V 4 75A an Inbetriebnahme Verbinden Sie mindestens eines der mitgelieferten Tischnetzteile mit einer Netzsteckdose HINWEIS M...

Page 9: ...eschlossen In Red an Die externe redundante Spannungsversorgung Red liefert die erforderliche Spannung aus Die externe redundante Spannungsversorgung Red ist ausgeschaltet oder nicht angeschlossen Pow...

Page 10: ...al eine OSD Nachricht Abh ngig davon ob Sie die PS 2 Maus oder PS 2 Tastatur Schnittstelle verbunden haben werden die Leitungen ber die Kontakte K1 K2 Tastatur oder M3 M4 Maus berwacht HINWEIS Nach Ak...

Page 11: ...je 1 5 A Stromversorgung Typ externes Netzteil Anzahl 2 Anschluss Mini DIN 4 Power Buchse Spannung 12VDC Stromaufnahme 3 0 A Geh use Material Aluminium eloxiert Ma e B H T 105 mm 26 mm 84 mm Gewicht c...

Page 12: ...tor G D will not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt of good...

Page 13: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there...

Page 14: ...Table of contents iii G D MultiPower 2 12V Contents Safety instructions 1 Introduction 3 Scope of delivery 3 Installation 4 Start up 4 Status LEDs 5 Status Output sockets 6 Technical data 7...

Page 15: ...l installation assurez vous que l appareil a t d branch de toutes les sources d alimentation D branchez toutes les fiches d alimentation et toutes les alimenta tions lectrique de l appareil Trennen S...

Page 16: ...devices ensure that the power plugs remain accessible Avoid tripping hazards Avoid tripping hazards while laying cables Operate the device only in designated areas The devices are designed for indoor...

Page 17: ...e devices to a Mini DIN 4 socket of the central power supply At least one external power supply table power pack supplies the voltage of the central power supply A second external power supply ensures...

Page 18: ...one of the table power packs 12V 4 75A Red Connect one of the table power packs 12V 4 75A Start up Connect at least one of the table power packs with a power socket NOTE The central power supply suppl...

Page 19: ...hed off or not connected In Red On The external redundant power supply Red provides the required voltage Off The external redundant power supply Red is switched off or not connected Power Out 1 On Pow...

Page 20: ...D message Depending on whether you connected the PS 2 mouse or PS 2 keyboard interface the lines are monitored via contacts K1 K2 keyboard or M3 M4 mouse NOTE After activating the GPIO function in the...

Page 21: ...r supply Type External power pack Quantity 2 Connection Mini DIN 4 power socket Voltage 12VDC Power consumption 3 0 A Housing Material Anodised aluminium Dimensions W H D 105 mm 26 mm 84 mm Weight App...

Page 22: ......

Page 23: ...English...

Page 24: ...bere Leimbach 9 57074 Siegen Germany www gdsys de sales gdsys de Das Handbuch wird fortlaufend aktualisiert und im Internet ver ffentlicht The manual is constantly updated and available on our website...

Reviews: