»Status Output« sockets
6
· G&D MultiPower-2-12V
»Status Output« sockets
The
Status Output
sockets of the central power supply help you monitor the incoming
power supply.
For this, you can use the GPIO function of
compatible
console or target modules (see
Config Panel 21
manual).
To monitor the central power supply, connect a
Status Output
socket to a PS/2
mouse
or
PS/2 keyboard interface of a compatible console or target module.
Now use the console or target module to configure the two lines of this interface (
K1/
K2
or
M3/M4
) as input and optionally enter an OSD message.
Depending on whether you connected the PS/2 mouse
or
PS/2 keyboard interface,
the lines are monitored via contacts
K1/K2
(keyboard) or
M3/M4
(mouse):
NOTE:
After activating the GPIO function in the configuration of a console
module or a target module, two lines of the PS/2 mouse and PS/2 keyboard inter-
face can receive signals from the outside (input) or transmit signals to the outside
(output).
Line
Status
Meaning
Line 1
(K1/M3)
Enabled
The external main power supply (
Main
) provides the
required voltage.
Disabled
The external main power supply (
Main
) is switched off
or not connected.
Line 2
(K2/M4)
Enabled
The external redundant power supply (
Red.
) provides the
required voltage.
Disabled
The external redundant power supply (
Red.
) is
switched off or not connected.
Summary of Contents for MultiPower-2-12V
Page 22: ......