background image

'(7$,/'

6&$/(

6833/<0$,1/,1(

5(78510$,1/,1(

'(7$,/$$

6&$/(

5(78510$,1/,1(

6833/<0$,1/,1(

'(7$,/$+

6&$/(

6833/<

5(7851

7(03&21752/

5(9,6,216

=21(

5(9

'(6&5,37,21

'$7(

$33529('

'

&

%

$

$

%

&

'

(

)

(

),5($1',&(72(;,67,1*

*/<&2/6<67(03,3,1*

&200,77('72&2/'

 

(67

760

BAILEY HILL RD.

(8*(1(257(/

* '&+,//(56

Summary of Contents for FIRE AND ICE

Page 1: ...1 800 555 0973 INFO GDCHILLERS COM GDCHILLERS COM INSTALLATION VIDEOS FIRE AND ICE PORTABLE CHILLER HEATER INSTALLATION GUIDE USER MANUAL...

Page 2: ...I 2 FIRE ICE MANUAL 2020 G D CHILLERS INC ALL RIGHTS RESERVED...

Page 3: ...CONTACT INFORMATION AFTERHOURS SUPPORT 4 INSTALLATION VIDEO LINKS 4 PACKAGE CHILLER DESCRIPTION 5 INSTALLATION REQUIREMENTS 6 PIPING RECOMMENDATIONS 7 START UP INSTRUCTIONS 13 WARRANTY START UP CHECKL...

Page 4: ...ecording will provide contact information for the emergency on call service technician INSTALLATION VIDEO LINKS Visit the following pages for installation video walk throughs and FAQs gdchillers com i...

Page 5: ...k to tank without damage to system or pump Copper and bronze construction REFRIGERANT PIPING Type L ACR copper Liquid line filter drier sight glass moisture indicator solenoid valve and thermal expans...

Page 6: ...A plug that meets the electrical requirements of the system and the environmental requirements of the space where the system will be used Must be installed by a qualified electrician 3 Unit must be p...

Page 7: ...o them for the first time Individual temperature control package should be installed at each vessel to maintain optimal conditions for each process being heated or cooled by the Fire and Ice unit Glyc...

Page 8: ...7 6 6833 0 1 1 5 7851 0 1 1 7 6 5 7851 0 1 1 6833 0 1 1 7 6 6833 5 7851 7 03 21752 5 9 6 216 21 5 9 6 5 37 21 7 33529 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 9: ...7 6 5 7851 6833 6 7 21 6 2 1 2 7 1 6 3257 5 7 5 6833 5 7851 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 10: ...6833 2 2 2 6833 0 1 1 5 7851 0 1 1 0 1 080 7 5 1 7 6 0 1 080 7 7 6 2 1 2 5 2 5 2 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 11: ...6833 7 6 6833 5 7851 7 6 0 6 675 1 5 6 39 3 3 3 3 5 8 5 758 81 21 9 9 758 81 21 9 9 9 9 7 0 6 6833 5 7851 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 12: ...6833 5 7851 7 6 9 9 7 6 7 03 21752 7 6 48 6 211 7 92 7 62 12 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 13: ...lycol in reservoir temporarily close the supply valve and confirm glycol pressure is at 20 PSI or under lowest jacket pressure rating whichever is lowest 4 Turn the door switch back OFF and the compre...

Page 14: ...1 L2 L3 PUMP ROTATION GLYCOL PRESSURE COMPRESSOR A COMPRESSOR B COMPRESSOR C COMPRESSOR D CRANK CASE HEATER ENGERGIZED 4 HOURS COMPRESSOR OIL LEVEL MOTOR AMPS L1 L1 L1 L1 L2 L2 L2 L2 L3 L3 L3 L3 SUPER...

Page 15: ...rate G D Chillers Preventive Maintenance Checklist for a complete list of maintenance tasks Contract a licensed refrigeration technician to evaluate the chiller refrigeration circuit s regularly These...

Page 16: ...eak or system undercharged Check for leaks repair and recharge Plugged filter drier Replace filter drier Insufficient subcooling Check condenser subcooling circuit 4 Suction pressure too high Glycol t...

Page 17: ...oil level or phase reversal Check oil level Restart 3 ph compressor by switching 2 phases replace if it does not restart 9 Compressor starts but start relay does not drop out High running current over...

Page 18: ...See items 3 and 5 Leaking liquid line solenoid valve LLSV Replace LLSV Leaking compressor valves Replace compressor Undercharged system Check for leaks and recharge 13 Internal pressure safety valve...

Page 19: ...5 38 0 2 4 28 0 38 2 38 7 3 7 28 4 38 5 39 0 4 2 28 5 For most applications G D Chillers recommends no less than and no more than 35 propylene mixture The volume percentages in this table apply for pu...

Page 20: ...0 days from warranty service or exchange whichever is longer Any upgrade to the original product will be covered only for the duration of the original warranty period EXCLUSIONS This warranty does not...

Page 21: ...WARRANTY TO THE EXTENT PERMITTED BY APPLICABLE LAW G D CHILLERS INC DOES NOT WARRANT THAT THE OPERATION OF ANY PRODUCTS COVERED UNDER THIS LIMITED WARRANTY WILL MEET YOUR REQUIREMENTS OR THIRD PARTY...

Page 22: ...LATION GUIDE USER MANUAL FIRE ICE PORTABLE CHILLER HEATER 22 G D CHILLERS INC GD MNL_FNI_PM6 R2020A G D Chillers welcomes any and all questions or concerns We can be reached at 800 555 0973 or 541 345...