TO THE EXTENT  THAT ANY OF THE SAME CANNOT BE EXCLUDED, SUCH IMPLIED CONDITION, REPRESENTATION 

AND/OR WARRANTY IS LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD REFERRED TO IN THE "LIMITED 

WARRANTY" SECTION ABOVE. BECAUSE SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS ON HOW 

LONG AN IMPLIED WARRANTY LASTS, THE ABOVE LIMITATION MAY NOT APPLY IN SUCH STATES. THIS WARRANTY 

GIVES THE CUSTOMER SPECIFIC LEGAL RIGHTS, AND THE CUSTOMER MAY ALSO HAVE OTHER RIGHTS WHICH VARY 

FROM JURISDICTION TO JURISDICTION. 

DISCLAIMER OF LIABILITY 

G&D CHILLERS, INC.'S TOTAL LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES RESULTING FROM ANY CAUSE 

WHATSOEVER INCLUDING G&D CHILLERS, INC.’S NEGLIGENCE, ALLEGED DAMAGE, OR DEFECTIVE GOODS, WHETHER 

SUCH DEFECTS ARE DISCOVERABLE OR LATENT, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCT. 

G&D  CHILLERS,  INC.  SHALL  NOT  BE  RESPONSIBLE  FOR  LOSS  OF  USE,  WORK  STOPPAGE,  FAILURE  OF  OTHER 

EQUIPMENT TO WHICH THE PRODUCT IS CONNECTED, COMMERCIAL LOSS, LOST REVENUE OR LOST PROFITS, LOSS 

OF  GOODWILL,  LOSS  OF  REPUTATION,  OR  OTHER  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES.  NO  ORAL  OR 

WRITTEN  REPRESENTATIONS  MADE  BY  G&D  CHILLERS,  INC.  SHALL  CREATE  ANY  ADDITIONAL  WARANTY 

OBLIGATIONS,  INCREASE  THE  SCOPE,  OR  OTHERWISE  MODIFY  IN  ANY  MANNER  THE  TERMS  OF  THIS  LIMITED 

WARRANTY. TO THE EXTENT PERMITTED BY APPLICABLE LAW, G&D CHILLERS, INC. DOES NOT WARRANT THAT THE 

OPERATION OF ANY PRODUCTS COVERED UNDER THIS LIMITED WARRANTY WILL MEET YOUR REQUIREMENTS, OR 

THIRD  PARTY  SERVICES,  BE  UNINTERRUPTED,  ERROR-FREE,  OR  THAT  DEFECTS  IN  THE  PRODUCTS  WILL  BE 

CORRECTED. SOME STATES DO NOT ALLOW THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE 

ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, 

AND  YOU  MAY  ALSO  HAVE  OTHER  RIGHTS,  WHICH  VARY  FROM  STATE  TO  STATE.  THIS  LIMITED  WARRANTY  IS 

SUBJECT TO CHANGE WITHOUT NOTICE. CHECK www.gdchillers.com FOR THE MOST CURRENT VERSION OF THIS 

WARRANTY.  

SEVERABILITY 

In the event that any term or provision contained in this limited warranty is found to be invalid, illegal or 

unenforceable by a court of competent jurisdiction, then such provision shall be deemed modified to the 

extent necessary to make such provision enforceable by such court, taking into account the intent of the 

parties. The invalidity in whole or in part of any portion of this limited warranty shall not impair or affect 

the validity or enforceability of the remaining provisions of this limited warranty. 

HOW TO OBTAIN WARRANTY SERVICE (PRE-AUTHORIZATION REQUIRED) 

To obtain warranty service, contact G&D CHILLERS, INC.: 

1.

Email: [email protected]

2.

Phone: (800) 555-0973 from 9:00AM to 5:00PM Monday through Friday Pacific Time.

3.

By mail:   G&D Chillers, Inc.

760 Bailey Hill Rd 

Eugene, OR 97402 

Summary of Contents for FIRE AND ICE

Page 1: ...1 800 555 0973 INFO GDCHILLERS COM GDCHILLERS COM INSTALLATION VIDEOS FIRE AND ICE PORTABLE CHILLER HEATER INSTALLATION GUIDE USER MANUAL...

Page 2: ...I 2 FIRE ICE MANUAL 2020 G D CHILLERS INC ALL RIGHTS RESERVED...

Page 3: ...CONTACT INFORMATION AFTERHOURS SUPPORT 4 INSTALLATION VIDEO LINKS 4 PACKAGE CHILLER DESCRIPTION 5 INSTALLATION REQUIREMENTS 6 PIPING RECOMMENDATIONS 7 START UP INSTRUCTIONS 13 WARRANTY START UP CHECKL...

Page 4: ...ecording will provide contact information for the emergency on call service technician INSTALLATION VIDEO LINKS Visit the following pages for installation video walk throughs and FAQs gdchillers com i...

Page 5: ...k to tank without damage to system or pump Copper and bronze construction REFRIGERANT PIPING Type L ACR copper Liquid line filter drier sight glass moisture indicator solenoid valve and thermal expans...

Page 6: ...A plug that meets the electrical requirements of the system and the environmental requirements of the space where the system will be used Must be installed by a qualified electrician 3 Unit must be p...

Page 7: ...o them for the first time Individual temperature control package should be installed at each vessel to maintain optimal conditions for each process being heated or cooled by the Fire and Ice unit Glyc...

Page 8: ...7 6 6833 0 1 1 5 7851 0 1 1 7 6 5 7851 0 1 1 6833 0 1 1 7 6 6833 5 7851 7 03 21752 5 9 6 216 21 5 9 6 5 37 21 7 33529 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 9: ...7 6 5 7851 6833 6 7 21 6 2 1 2 7 1 6 3257 5 7 5 6833 5 7851 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 10: ...6833 2 2 2 6833 0 1 1 5 7851 0 1 1 0 1 080 7 5 1 7 6 0 1 080 7 7 6 2 1 2 5 2 5 2 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 11: ...6833 7 6 6833 5 7851 7 6 0 6 675 1 5 6 39 3 3 3 3 5 8 5 758 81 21 9 9 758 81 21 9 9 9 9 7 0 6 6833 5 7851 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 12: ...6833 5 7851 7 6 9 9 7 6 7 03 21752 7 6 48 6 211 7 92 7 62 12 5 1 72 67 1 2 6 67 0 3 3 1 200 77 72 2 67 760 BAILEY HILL RD 8 1 25 7 56...

Page 13: ...lycol in reservoir temporarily close the supply valve and confirm glycol pressure is at 20 PSI or under lowest jacket pressure rating whichever is lowest 4 Turn the door switch back OFF and the compre...

Page 14: ...1 L2 L3 PUMP ROTATION GLYCOL PRESSURE COMPRESSOR A COMPRESSOR B COMPRESSOR C COMPRESSOR D CRANK CASE HEATER ENGERGIZED 4 HOURS COMPRESSOR OIL LEVEL MOTOR AMPS L1 L1 L1 L1 L2 L2 L2 L2 L3 L3 L3 L3 SUPER...

Page 15: ...rate G D Chillers Preventive Maintenance Checklist for a complete list of maintenance tasks Contract a licensed refrigeration technician to evaluate the chiller refrigeration circuit s regularly These...

Page 16: ...eak or system undercharged Check for leaks repair and recharge Plugged filter drier Replace filter drier Insufficient subcooling Check condenser subcooling circuit 4 Suction pressure too high Glycol t...

Page 17: ...oil level or phase reversal Check oil level Restart 3 ph compressor by switching 2 phases replace if it does not restart 9 Compressor starts but start relay does not drop out High running current over...

Page 18: ...See items 3 and 5 Leaking liquid line solenoid valve LLSV Replace LLSV Leaking compressor valves Replace compressor Undercharged system Check for leaks and recharge 13 Internal pressure safety valve...

Page 19: ...5 38 0 2 4 28 0 38 2 38 7 3 7 28 4 38 5 39 0 4 2 28 5 For most applications G D Chillers recommends no less than and no more than 35 propylene mixture The volume percentages in this table apply for pu...

Page 20: ...0 days from warranty service or exchange whichever is longer Any upgrade to the original product will be covered only for the duration of the original warranty period EXCLUSIONS This warranty does not...

Page 21: ...WARRANTY TO THE EXTENT PERMITTED BY APPLICABLE LAW G D CHILLERS INC DOES NOT WARRANT THAT THE OPERATION OF ANY PRODUCTS COVERED UNDER THIS LIMITED WARRANTY WILL MEET YOUR REQUIREMENTS OR THIRD PARTY...

Page 22: ...LATION GUIDE USER MANUAL FIRE ICE PORTABLE CHILLER HEATER 22 G D CHILLERS INC GD MNL_FNI_PM6 R2020A G D Chillers welcomes any and all questions or concerns We can be reached at 800 555 0973 or 541 345...

Reviews: