background image

INDOOR
BLOWER
MOTOR

BR

BR

CAP

T

GND

LINE V

24 V

LINE V

24 V

BK
BL
BR
GR
OR
RD
RD/BK
VI
WH
YL
F
T
CAP
AL
L
GND

BLACK
BLUE
BROWN
GREEN
ORANGE
RED
RED/BLACK STRIPE
VIOLET
WHITE
YELLOW
LOW SPEED FAN SWITCH
TRANSFORMER
STARTING CAPACITOR
AUXILARY LIMIT
LIMIT
GROUND

LEGEND

PRINTED CIRCUIT
BOARD WIRING

FACTORY WIRING

FIELD WIRING

ORANGE WIRE NUT

GROUND

=  TERMINAL PROVIDED

=  TERMINAL NOT PROVIDED

WIRE NUT CONNECTIONS
FACTORY WIRING

UNUSED

MOTOR

LEADS

B
U
R
N
E
R

1

1

1

4

7

2

3

3

X

H
U
M

C

4

5

6

N

7

S
2

E
A
C

C
O
N
T

C
O
O
L

H
E
A
T

H M

L

C

F

12

2

1

3

5

4

6

8

7

9

1

2

1

2

60 Sec.

1

2

90 Sec.

DELAY  OFF  DIP  SWITCH  SETTINGS

1

2

1

2

1

2

120 Sec.

1

2

150 Sec.

L1(H)

N3

S2

K2

K2

K1

K1

N2

N2

L1

0

L2(N)

LOW SPEED HEAT 
CONNECTION

MEDIUM SPEED 

HEAT CONNECTION

GND

COOL

HIGH
LOW

MED

HIGH

MED

LOW

HEAT

HEAT

CONSTANT

COOL

CN6-9

CN6-1

C

LIMIT

CN6-6

CN6-3

S1

N1

X

N4

S3

CN6-2

CN6-7

CN6-8

BURNER

MOTOR

PRIMARY

ACCESSORY

120VAC

24VAC

LIMIT SENSE

OIL ELECTRONIC FAN TIMER

GND

TRANSFORMER

CN6-4

CONSTANT

LOW SPEED

FAN SWITCH

LOW SPEED

FAN SWITCH

UNUSED MOTOR LEAD

L2

UNUSED MOTOR LEAD

CIRCULATION BLOWER

CIRCULATION 

BLOWER

CIRCULATION 

BLOWER

K1, K2

CONTROL

K3

TSTAT

R

W

Y

G

C

T1         T2

PRIMARY

115 VAC 1

ø 

60HZ POWER SUPPLY

(FUSED DISCONNECT ON HOT LEG)

(1) MAKE FIELD POWER SUPPLY CONNECTIONS TO BLACK AND WHITE WIRES CAPPED 
      WITH ORANGE WIRE NUTS.

(2) WARNING--- UNIT MUST BE GROUNDED. WIRING MUST CONFORM TO N.E.C. AND 
      LOCAL CODES. IN CANADA WIRING MUST CONFORM TO CURRENT CSA 22.1 CANADIAN
      ELECTRICAL CODE PART 1 AND/OR LOCAL CODES.

(3) IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED,
     IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF 
     AT LEAST 105

°

 C AND BE A MINIMUM OF 16 GA. AWG COPPER STRAND WIRE. USE 

     COPPER WIRE ONLY FOR FIELD WIRING.

(4) CONNECT REQUIRED MOTOR LEAD TO HEAT TERMINAL ON CIRCUIT BOARD TO DELIVER 
      A TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

(5) SET THE HEAT ANTICIPATOR ON THE THERMOSTAT AT .2 AMPS.

(6) FOR ELECTRICAL LOAD AMPERES, BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE 
      SIZE SEE FURNACE MODEL LABEL.

(7) HUM TERMINAL IS 115V.

H M

L

C

INDOOR
BLOWER
MOTOR

LOW SPEED HEAT
CONNECTION DETAIL

BR

BR

CAP

UNUSED

MOTOR

LEADS

B
U
R
N
E
R

1

1

2

3

3

4

S
2

E
A
C

C
O
N
T

C
O
O
L

H
E
A
T

F

1   2   3   4

RD

RD

RD/BK

WH

BK

BL

YL

RD

RD

L

FIXED COOL 
ANTICIPATOR

ADJUSTABLE
HEATING
ANTICIPATOR

TEMP

FALL

TYPICAL THERMOSTAT

COOL

OFF

FAN

AUTO

ON

HEAT

W

R1

W1 Y1

G

W

R

Y

C

I

Y

R

G

DELAY OFF

SELECTION

DIP SWITCH

DELAY OFF

SELECT

CN6

VI

BK

BURNER

MOTOR

WH

WH

CN6

WH

OR

YL BL

BK

L1

L2

ORANGE

FLAME DETECT

ENLARGED TOP VIEW

CAD CELL

(BLACK)(WHITE)

INTERUPTED OIL PRIMARY CONTROL

T1

T2

BK

OR

COOLING
CONTACTOR
(IN AIR 
CONDITIONER, 
IF USED)

WH

BK

L1 (H)

L2 (N)

GND

BL

YL

WH

- - -

- - -

- - -

- - -

- - -
- - -

1   2   3   4

BK

WH

RD

RD

YL

BL

Honeywell

NOTES:

 POWER SUPPLY
115 VAC /1Ø 60 HZ
(FUSED DISCONNECT ON HOT LEG)

MEDIUM SPEED

HEAT CONNECTION

ST9103

N5

ELECTRONIC AIR

CLEANER

(OPTIONAL)

EAC

HUM

N6

HUMIDIFIER

(OPTIONAL)

SEE

NOTE 7

FACTORY SET

HEATING SPEED

105-- MED (M)
125-- MED (M)

155-- HIGH (H)

A96380

Fig. 7−Wiring Diagram

—14—

Summary of Contents for PO8LAA

Page 1: ...OIL CONNECTIONS 6 BAROMETRIC DRAFT CONTROL 6 ELECTRICAL 6 FILTERS 6 OPERATIONAL CHECKOUT 6 START UP 6 RECOMMENDED INSTALLATION PRACTICES AND COMBUSTION CHECK 7 FAN ADJUSTMENT CHECK 7 LIMIT CONTROL CH...

Page 2: ...of above codes should be used and are available from either The National Fire Protection Agency Batterymarch Park Quincy MA 02269 or The Canadian Standards Association 178 Rexdale Blvd Rexdale Ontari...

Page 3: ...regulator included with furnace shall be installed in same room or enclosure as furnace in such a manner as to prevent any difference in pressure between regulator and combustion air requirements Air...

Page 4: ...impose proper static at outlet of furnace 2 A flexible duct connector of noncombustible material should be installed at unit on both supply and return air systems In applications where extremely quie...

Page 5: ...ey flue is clear of any dirt or debris 2 Be sure that chimney is not servicing an open fireplace 3 Never reduce pipe size below minimum certified furnace pipe size shown in Table 2 4 All pipe should b...

Page 6: ...conduit where required used may terminate at side panel of unit It is not necessary to extend conduit inside unit from side panel to control box When replacing any original furnace wiring use only 105...

Page 7: ...e nozzle oil pressures of 100 psig The firing rate noted on nameplate may be obtained with standard nozzles by adjusting pump pressure as noted in Table 4 or on label on furnace On a new installation...

Page 8: ...ubes and possibly heat exchanger drum section Removal of any heat exchanger components which are sealed by gaskets requires replacement of gasket WARNING Failure to replace any heat exchanger gaskets...

Page 9: ...and vacuum cleaner 6 Before reinstalling cleanout port covers the gasket on each cover MUST be replaced Use cleanout port gasket kit part no 20196201 7 Reinstall covers and tighten in place making sur...

Page 10: ...er forward out of heat exchanger Be careful not to bump combustion chamber as it becomes brittle after having been fired 17 Use a stiff brush and vacuum cleaner to clean inside of primary drum 18 Befo...

Page 11: ...d on inside of louvered door to properly rewire unit PROCEDURE 5 KEEPING FILTERS CLEAN WARNING Never operate unit without a filter or with filter access door removed Failure to adhere to this warning...

Page 12: ...epth Height A B C D E F G H 036105 22 52 33 20 17 1 4 6 25 1 4 18 048125 22 57 33 20 22 1 4 6 30 1 4 18 060155 22 57 33 20 22 1 4 6 30 1 4 18 A96309 INSULATION INTERMEDIATE PANEL FILTER B A G D ELECTR...

Page 13: ...Fig 6 Barometric Damper Locations A95117 FIG A FIG G FIG D FIG L FIG B FIG C FIG J FIG H FIG K POOR WRONG WRONG WRONG WRONG WRONG BAROMETRIC DAMPER LOCATIONS GOOD LOCATIONS BAD LOCATIONS 13...

Page 14: ...DES IN CANADA WIRING MUST CONFORM TO CURRENT CSA 22 1 CANADIAN ELECTRICAL CODE PART 1 AND OR LOCAL CODES 3 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED...

Page 15: ...15...

Page 16: ...2000 CAC BDP P O Box 70 Indianapolis IN 46206 impo8l03 16 Catalog No 63PO 8LI...