BLOWER MOTOR SPECIFICATIONS AND AIRFLOW ADJUSTING DATA
Adjusting Airflow
MODEL
MOTOR
HP
BLOWER
WHEEL
HEAT SETTING
COOL SETTINGS
ADJUST
HEAT
COOL CFM @ .50 STATIC
HEATING CFM
ADJUSTMENT
SETTING "A"
SETTING "B"
SETTING "C"
SETTING "D"
EV050U3
1/2
10 X 6
NORM
A
NORM
1200
1000
800
600
LOW FIRE
600
( + )
1380
1150
920
690
HIGH FIRE
775
( - )
1020
850
680
510
EV075U3
1/2
10 X 6
NORM
A
NORM
1200
1000
800
600
LOW FIRE
1000
( + )
1380
1150
920
690
HIGH FIRE
1230
( - )
1020
850
680
510
EV100U4
3/4
12 X 9
NORM
A
NORM
1600
1400
1200
1000
LOW FIRE
1240
( + )
1800
1610
1380
1150
HIGH FIRE
1550
( - )
1360
1190
1020
850
EV125U5
1
12 X 12
NORM
A
NORM
2000
1800
1600
1400
LOW FIRE
1250
( + )
2200
2070
1840
1610
HIGH FIRE
1940
( - )
1700
1530
1360
1190
When operating the furnace in the heating mode, the static pressure and the temperature rise (supply air temperature
minus return air temperature) must be within those limits specified on the rating label. Failure to follow this warning
could lead to severe furnace damage.
Turn OFF all gas and electrical power to furnace before performing any maintenance or service on unit. (Unless
specific test requires gas and electrical supplies.) Failure to take this precaution may result in personal injury due
to electrical shock or uncontrolled gas leakage.
20558801
Issue 0442
Page 4 of 32
Summary of Contents for Gas-Fired Furnace
Page 13: ...FURNACE WIRING SPECIFICATIONS 20558801 Issue 0442 Page 5 of 32 ...
Page 21: ...Figure 8 20558801 Issue 0442 Page 13 of 32 VENT TERMINATION CLEARANCES ...
Page 36: ...SEQUENCE OF OPERATION DIRECT IGNITION SYSTEM CONTROL 20558801 Issue 0442 Page 28 of 32 ...
Page 40: ...WIRING DIAGRAM 20558801 Issue 0442 Page 32 of 32 ...