SAFETY
The following is a list of safety precautions and their locations in this manual.
These safety rules and precautions must be followed when installing this furnace.
1. Use only with type of gas approved for this furnace. Refer to the furnace rating
plate.
2. Install this furnace only in a location and position as specified in
The
Location/Placement Section on page 6
of these instructions.
3. Provide adequate combustion and ventilation air to the furnace space as
specified in
Air for Combustion and Ventilation section on page
8 of these
instructions.
4. Combustion products must be discharged outdoors. This furnace requires a
special vent system with adequate clearances around the vent-air intake terminal
(s), as specified in
Venting on page
12 of these instructions.
5. As a TYPE FSP CATEGORY IV furnace the combustion air connections, the flue
gas connection, the vent-air intake terminal and condensate trap and drain
system must be as specified in the
Venting section starting on page
12 of these
instructions. Venting and drain materials must be as specified and are to be
supplied by the installer. On direct vent systems the vent outlet shall be installed
so as to be in the same atmospheric pressure zone as the combustion air intake.
6. Never test for gas leaks with an open flame. Use a commercially available soap
solution made specifically for the detection of leaks to check all connections, as
specified in
The Gas Connection section on page
19 of these instructions.
7. Always install furnace to operate within the furnace's intended temperature-rise
range with a duct system which has an external static pressure within the
allowable range, as specified in
Furnace Specifications on page
3 of these
instructions. See furnace rating plate.
8. When a furnace is installed so that supply ducts carry air circulated by the
furnace to areas outside the space containing the furnace, the return air shall
also be handled by duct(s) sealed to the furnace casing and terminating outside
the space containing the furnace.
See page 11
for Ducting.
9. A gas-fired furnace for installation in a residential garage must be installed as
specified in
The Location / Placement section on page
6 of these instructions.
10. The furnace is not to be used for temporary heating of buildings or structures
under construction. As noted on page 6 under Introduction.
20558801
Issue 0442
Page 2 of 32
Summary of Contents for Gas-Fired Furnace
Page 13: ...FURNACE WIRING SPECIFICATIONS 20558801 Issue 0442 Page 5 of 32 ...
Page 21: ...Figure 8 20558801 Issue 0442 Page 13 of 32 VENT TERMINATION CLEARANCES ...
Page 36: ...SEQUENCE OF OPERATION DIRECT IGNITION SYSTEM CONTROL 20558801 Issue 0442 Page 28 of 32 ...
Page 40: ...WIRING DIAGRAM 20558801 Issue 0442 Page 32 of 32 ...