Inside the console there is a terminal strip for connecting the principal
electrical wire (not supplied) to the unit. The electrical connection of the
unit must only be carried out by a qualified electrician.
NB:
To ensure that the unit works correctly, the electrical supply must meet the
specifications indicated on page six of this manual and appearing on the machine
specifications plate.
Follow the recommended procedure in the indicated order to install the unit:
a) Insert the main power cable by passing it through the wire stop at the bottom of the
electrical console and connect as shown in the diagram.
Use the proper size of cable according to the voltage, current and maximum power required by
the Unit.
The sizing of the cable is calculated for a length of 25m, for longer lengths you must
recalculate the appropriate section.
56,0 A @ 3PE~400V
100 A @ 3PE~230V
Cable Section 10 mm
2
Cable Section 16 mm
2
Make sure the power cable is disconnected from the mains source before connecting it
to the terminal strip in the console.
b) Load 63 liters (16.6 gal) of hydraulic fluid into
the tank of the unit. The oil must be of the
characteristics and specifications of DIN
51524 standard, sections 1 and 2 (for
example. ISO VG 46).