evolution G-50 H
Service Manual
10/48
Issue 3.2
16. DIP S1 Selector TPC Probes
This sets the hose heating control mode
to be selected, depending on whether
the
system
includes
a
single
Temperature Control Sensor (TCS) for
automatic temperature control or no
TCS for manual temperature control.
Please
be
aware
that
after
manipulating the DIP selector you
should switch off the unit so the
change. (in detected buy the board).
17. DIP S2 Selector Control Units
This sets the pressure and temperature
units that will be shown on the control
panel displays to Metric or English. Set
to EU for the pressure to be shown in
bar
and the temperature to be shown in
degrees Celsius. Set to USA for the
pressure to be shown in
psi
and the
temperature to be shown in degrees
Fahrenheit.
Please be aware that after
manipulating the DIP selector you
should switch off the unit so the
change. (in detected buy the board).
18. DIP S3 selector
– Input Voltage selector
It allows selecting the input voltage. Moving the 1 switch to ON for 230V with neutral and to OFF
for 400V without neutral. Selection is factory set and cannot be modified without HI-TECH
technical service authorization.
Please be aware that after manipulating the DIP selector
you should switch off the unit so the change (in detected buy the board).