evolution G-35 H
Service Manual
19/45
Issue 1.9
Ref. NR-00103-ENG
http://www.gamapur.com/
Make sure the power cable is disconnected from the
mains source before connecting it to the terminal
strip in the console.
b) Load 63 liters (16.6 gal) of hydraulic fluid into the
tank of the unit. The oil must be of the
characteristics and specifications of DIN 51524
standard, sections 1 and 2 (for example. ISO VG
46).
PRECAUTION!
Do not fill the tank to maximum capacity (78 Lts
–
20.6 gal); make sure the amount of oil is not more than 80% of its
maximum capacity (63 Lts.
– 16.6 gal). Use the visual level indicator
of temperature on the tank as a reference, because the maximum
temperature limit (80ºC
– 176ºF) coincides with the advised
capacity.
c) Check the level of the oil in the case of the hydraulic pump:
remove the plug from the top of the pump case and check that
the oil level reaches to the top of the case. Add oil if necessary
and refit the plug.
d) Fill the lube reservoir of the Isocyanate pump with DOTP. It is
not necessary to prime the system.
e) Connect the hoses of the products to the outlets of the
respective heaters (the Isocyanate hose to the Isocyanate
heater and the Polyol hose to the Polyol heater).